11.6 EVENTS

DISPLAY SEL FLASH Description
W001
1
Encoder error
W002
1
Motor short circuit
W003
1
Motor circuit error
W010
2
Inverted movement
W011
2
Stroke too long.
W012
2
Stroke too short
W013
2
Beyond stroke
W030
5
Emergency card not detected
W031
5
Communication shut-off
W032
5
Emergency sensor input error
W033
5
Emergency opening test failure
W034
5
Motor relay error
W035
5
Lock position error
W036
5
Lock operating error
W037
5
Opening manoeuvre failure
W038
5
Emergency opening test failure
W039
5
Contact 1-KC closed for over 10 seconds
W100
-
-
Programming error (CB01)
W103
-
-
Programming error (FSD1)
W104
-
-
Programming error (CB02)
W127
-
-
Automation reset
W128
on
No mains power supply
W129
1
No battery
W130
1
Battery flat
W140
3
Safety test fail 6A
W141
3
Safety test fail 6B
W142
3
Safety test fail 8A
W143
3
Safety test fail 8B
W145
4
Excess motor temperature (first threshold)
W146
4
Excess motor temperature (second threshold)
W148
1
Locking device overcurrent
W150
2
Opening obstacle
W151
2
Closure obstacle
W152
2
Door locked in opening
W153
2
Door locked in closure
W160
1
Synchronisation error
W256
-
-
Start-up
W257
-
-
Firmware upgrade
W320
on
Maintenance signal
W330
1
Motor and electronic in sync
Notes
Check encoder connection
Check motor connection
Electronic control malfunction
Check the presence of obstacles
Check belt connection
Check the presence of obstacles
Check the presence of the mechanical limit switches
Electronic control malfunction
Electronic control malfunction
Electronic control malfunction
Check motor-electronic control connection
Electronic control malfunction
Check lock-micro switch connection
Check lock-micro switch connection
Check the presence of obstacles
Check motor-electronic control connection
Check connection to terminal KC
Repeat the programming procedure MEM>FW
Repeat the programming procedure SEL>FW
Repeat the programming procedure MEM>FW
The automation executes an auto-diagnosis
Check the mains power supply is present.
Check the battery connection
Replace or recharge the battery
Check connection of the safety sensor
Check connection of the safety sensor
Check connection of the safety sensor
Check connection of the safety sensor
The door reduces the speed
The door stops
Check the ADV>TYLK menu and connection of the lock
Check the presence of obstacles
Check the presence of obstacles
Check the presence of locks
Check the presence of locks
Check the menu ADV > SYNC and ADV > INK
-
-
Check INFO > SERV menu
Wait approx. 3-30 seconds