STG2
Input commands between terminals 1-G2. Choose from the following values.
G2-SETTING
NO = No function
STOP = Stop command (N.C.). Opening of the contact 1-G2 causes stoppage of the door (EMERGENCY
Selection not available for Emergency automations).
STEP = Step-step command Closure of the contact 1 - G2 causes in sequence opening (automatic closure
disabled) and closure of the door.
SAM = Automatic selection command of the function selector. Closure and opening of the contact 1-G2 changes
the functions selector mode (see menu settings: SEL > SAM1 and SEL > SAM2).
EMER = Emergency opening command (N.C.). Opening of the contact causes the door to open.
PART = Partial opening command (see menu settings: MENU > PART > 10-90).
CAB = Step-step command. Closure of the contact 1 - G2 causes in sequence closure of the door (commands
3A/3B disabled, room occupied signalling enabled) and opening of the door (re-enabling commands 3A/3B,
occupied room signalling disabled).
INKE = Interlocked operation bypass command between two doors (see menu: ADV > INK).
Output signalling between the terminals 0-G2 (12Vdc 20mA). Choose from the following values:
BELL = Output is activated for 3 seconds when the people come into the shop (by enabling in sequence the
safety contacts 1-8B and 1-8A).
SERV = Output is enabled when the door reaches the number of maintenance manoeuvres, set using the
menu: INFO > SERV.
WARN = Output is enabled when at least one alarm persists for 5 minutes. To reset alarm signalling to zero,
reset or disconnect power.
CLOS = Output is enabled when the door is closed
OPEN = Output is enabled when the door is open
LOCK = Output is enabled when the door is closed and locked
AIR = Output is enabled when the door is not closed
LAMP = Output is enabled when the door is in motion
CABS = Occupied room signalling (see menu setting: ADV > STG1 > CAB)
INK = Red traffic light signalling for interlocked doors (see menu: ADV > INK)

11.3 FUNCTIONS SELECTOR MENU

Using the buttons ↑ and ↓ choose the SEL menu, press ENTER to select and adjust the selector parameters.
Display
Description
MODE
Display the operating mode of the functions selector:
SELECTOR
NO = no mode present
MODE
OPEN = door open
AUTO = two-directional automatic operation
CLOS = door closed
1D = one-directional automatic operation
PA = partial automatic operation
1DPA = one-directional and partial automatic operation
SECL
Functions selector activation mode. Choose from the following values.
SELECTOR
NO = functions selector always accessible
LOCK
LOGO = functions selector accessible by selecting the logo for 3 seconds
TAG = functions selector accessible using the badge and numerical code
TMEM
Memorisation procedure of the badge and numerical code, choose the following values.
TAG
NO = no memorisation
MEMORIZE
SMOD = memorisation of the badge and numerical code for selector activation:
- press the ENTER key for 1 second, the display shows the writing REDY,
- move the badges close to the functions selector (in front of the NFC symbol), the display shows the badge code,
- wait 20 seconds or press the ESC key.
OPEN = memorisation of the badge and numerical code of priority opening; proceed as for SMOD.
N.B. If the badge or the numerical code is not recognised, the display will show the writing UNKN, or if the
badge or the numerical code is already saved, the writing NOK appears.
You can save an overall maximum of 50 badges and numerical codes.
20
Default settings
NO
Default settings
NO
NO
NO