myone LUCE R Manual De Instalación Y Mantenimiento página 12

Puertas correderas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1 - G1
Input terminal for general use.
Using the ADV menu > STG1, you can associate the G1 terminal with a specific function.
1 - G2
Input terminal for general use.
Output terminal (12 Vdc, 20mA max) for general use.
0 - G2
Using the ADV menu > STG2, you can associate the G2 terminal with a specific function.
1 - S1
N.C. contact of the limit switch of the locking device.
1 - 29
Reset N.O. contact. Closure and release of the contact starts the automatic detection manoeuvre of the stop measurements.
0 - 1 - H - L
Bus connection to functions selector
SD
Standard input for SD micro memory cards. Allows saving the settings of the door and loading the firmware upgrades.
Terminals
Description
R1 - R0
Current input for the opening sensor for emergency exits side A, internal side automation view (remove the jumper and resistance of
the terminals).
1 - EO
N.C. contact of emergency opening. Opening of the contact causes the door to open (connect the emergency opening device
and remove the jumper 1 - EO.
Buttons
Description
OPEN
Door opening button.
Button for menu scrolling and increase values selected.
Button for menu scrolling and reduce values selected.
ENTER
Button for menu scrolling and saving the data selected.
ESC
Menu exit button.
12