8.4 ELECTRICAL CONNECTIONS OF FUNCTIONS SELECTOR 31MP0005

Connect the terminals 0-1-H-L on the functions selector, using the cable not supplied by us, for terminals 0-1-H-L of the electronic
control.
N.B. For lengths over 10 metres, use a cable with 2 braided pairs.
After connection, the functions selector is working. If you want to limit use only by authorised staff, the proximity badges
(13.56MHz ISO15693 and ISO14443 Mifare) must be enabled using the functions selector menu (max 50 badges).
The functions selector allows the following settings.
Symbol
Description
DOOR OPEN
When selected, the symbol lights up and commands permanent opening of the door.
N.B. The leaves can however be manually moved.
TWO-DIRECTIONAL AUTOMATIC OPERATION
When selected, the symbol lights up and allows automatic operation of the door in two-directional mode with complete opening of the doors.
RESET
Select the symbol for 5 seconds, automation executes auto-diagnosis and learning of the stop measurements.
DOOR CLOSED
When selected, the symbol lights up and commands permanent closure of the door.
If the locking device is present, the leaves are closed and locked.
N.B. Using the SEL > DLAY menu, you can adjust the delay time to close the door.
PRIORITY CLOSURE
Selecting the symbol for 3 seconds, the automation slowly closes in "Low energy" mode and the safety devices are temporarily disabled.
PARTIAL AUTOMATIC OPERATION
When selected, the symbol lights up and allows automatic operation of the door with partial opening of the doors.
ONE-DIRECTIONAL AUTOMATIC OPERATION
When selected, the symbol lights up and allows automatic operation of the door in one-directional mode.
DISABLED FUNCTIONS SELECTOR SIGNALLING
The symbol lights up if the function selector is disabled. To enable temporary operation of the functions selector, you need to move the
badge to the symbol NFC (FSD1), or type the code (FSD4), or select the logo for 3 seconds.
FUNCTIONS SELECTOR VOLUNTARY ENABLING
Select the logo for 3 seconds (the lock symbol switches off), the functions selector is enabled for 10 seconds. Once the time is up, the
functions selector disables (the lock symbol lights up).
Authorised enabling of the functions selector via badge.
Move the badge towards the NFC symbol (the lock symbol switches off), the functions selector is enabled for 10 seconds. Once the time is
up, the functions selector disables (the lock symbol lights up).
BATTERY SIGNALLING
Battery off symbol = the door operates with mains power.
Battery on symbol = the door operates with battery power.
Flashing battery symbol = the battery is flat or disconnected.
INFORMATION SIGNALLING
Information symbol on = indicates you need to conduct routine maintenance of the door.
Flashing information symbol = indicates the presence of alarms:
- 1 flash = malfunctioning of the electronic control or locking device;
- 2 flashes = mechanical malfunction;
- 3 flashes = malfunctioning of the safety device test;
- 4 flashes = excess motor current.
- 5 flashes = Emergency electronic control malfunction