myone LUCE R Manual De Instalación Y Mantenimiento página 21

Puertas correderas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TDEL
Cancellation procedure of the badge and numerical code, choose the following values.
TAG DELETE
NO = no cancellation
YES = cancelled badge and numerical code.
- press the ENTER key for 1 second, the display shows the writing REDY,
- move the badges close to the functions selector (in front of the NFC symbol), the display shows the badge code,
- wait 20 seconds or press the ESC key.
N.B. if the badge or the numerical code is not recognised, the display shows the writing UNKN.
TMAS
You can create master badges that allow direct execution of saving operations of the badges and numerical
TAG MASTER
codes, without using the menu. Choose from the following values.
NO = no memorisation
MMOD = creation of the master badge and numerical code to save the badges and the numerical codes to
activate the selector: proceed as SMOD.
MOPE = creation of the master badge and numerical code to save the badges and the numerical codes for
priority opening: proceed as SMOD.
N.B. If the badge or the numerical code is not recognised, the display will show the writing UNKN, or if the
badge or the numerical code is already saved, the writing NOK appears.
The master badge is used as follows:
- place the saving master badge to the functions selector (in front of the symbol NFC), the buzzer emits 2 beeps
for the start of the saving procedure,
- place one badge at a time that you want to save to the functions selector (in front of the symbol NFC), the
buzzer emits 1 beep to confirm saving,
- wait 20 seconds, the buzzer emits 2 beeps for the end of the saving procedure.
N.B. if the badge or the numerical code is not saved, the buzzer will not beep.
DLAY
Door closed function delay time setting. Choose between the minimum and maximum value:
DELAY
minimum value = 1 s
CLOSED
maximum value = 5 min
DOOR
TERA
Procedure to delete all the badges and numerical codes saved. Choose from the following values:
TAG TOTAL
NO = no cancellation
ERASE
YES = cancellation of all the badges and numerical codes
SAM1
First selection of the functions selector, when the contact 1-G1 (1-G2) closes.
SELECTOR
Enable the SAM mode via the menu ADV > STG1 (STG2) > SAM. Connect the contact of a clock to the termi-
AUTOMATIC
nals 1-G1 (1-G2), and choose between the values:
MODE
OPEN = door open
AUTO = two-directional automatic operation
CLOS = door closed (EMERGENCY - In the event of Emergency automations, the door closed selection must
only be made using the functions selector)
1D = one-directional automatic operation
PA = partial automatic operation
1DPA = one-directional and partial automatic operation
SAM2
Second selection of the functions selector, when the contact 1-G1 (1-G2) opens.
SELECTOR
Enable the SAM mode via the menu ADV > STG1 (STG2) > SAM. Connect the contact of a clock to the termi-
AUTOMATIC
nals 1-G1 (1-G2), and choose between the values:
MODE
OPEN = door open
AUTO = two-directional automatic operation
CLOS = door closed (EMERGENCY - In the event of Emergency automations, the door closed selection must
only be made using the functions selector)
1D = one-directional automatic operation
PA = partial automatic operation
1DPA = one-directional and partial automatic operation
FW
Functions selector programming procedure. Insert the SD micro memory in the electronic control.
FIRMWARE
From this menu, choose the desired firmware version.
UPGRADE
Press the ENTER key until the programming procedure starts with a duration of approx. 30 seconds, at the end of
which the writing "SAVE" appears.
At the end of the procedure, remove the SD micro memory from the electronic control and keep it for future use.
N.B. In the event of a programming error or missing firmware (W103), proceed as follows: disconnect power, insert
the SD micro memory, power and repeat the programming procedure from the menu present.
VER
Displays the firmware version of the functions selector (for example = 0200).
VERSION
NO
NO
1
NO
CLOS
CLOS
- - - -
- - - -