Ref.
Code
1
2
3
4
5
6
7
8
8.1 GENERAL ELECTRICAL SAFETY WARNINGS
The installation, electrical connections and adjustments must be carried out in compliance with good practice and in compliance with standards in force.
Before connecting the electrical power supply, ensure the plate data correspond to those of the electrical distribution mains. On the power supply mains,
install an omnipolar switch/sectioning device with an opening distance of the contacts equal or over 3 mm. This switch must be protected from unauthorised
activations.
Check upstream of the electrical system that there is an adequate differential switch and an overcurrent safety device. When required, connect the automation
to an efficient earthing system installed as indicated by safety standards in force.
During installation, maintenance and repair operations, remove the power supply before opening the casing to switch on the electrical parts.
The electronic parts must be handled using anti-static, conductive wrist straps connected to the ground. MYONE S.r.l. cannot be held in any way liable if
components are installed which are incompatible for safety purposes and for good operation.
For possible repair or replacement of products, only original spare parts must be used.
8.2 ELECTRICAL POWER SUPPLY CONNECTION
Use the power cable supplied for connection to the power supply mains.
The power supply cable can be connected to an electrical socket (not supplied by us), prepared near the automation head.
If an electrical socket is not present near the automation, connect to the electrical mains as follows: perforate the aluminium box at the top, protect passage of
the power supply cable using cable glands (not supplied by us) to eliminate sharp edges which could damage the power cable, and connect the cable to the
electricity supply.
Connection to the electrical power supply, in the section outside automation, must takes place via an independent duct and separate from the connections to
the command and safety devices.
8.3 ELECTRONIC CONTROL TERMINAL BOARDS
When you connect the safety devices, remove the jumpers of the corresponding terminals.
ATTENTION: The terminals with equal number are equivalent.
The electronic control is supplied with the jumpers in the terminals with an asterisk [*]. When you connect the safety devices, remove the jumpers of the
corresponding terminals.
Terminals
Description
0 - 1
12 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals 1 (+ 12V).
1 - 3A
N.O. opening contact side A (internal side of automation view)
1 - 3B
N.O. opening contact side B (external side of automation view)
1 - KO
N.O. contact of priority opening, to connect to the devices only accessible to authorised staff using keys or codes.
1 - KC
N.O. contact of priority closure, to connect to the devices only accessible to authorised staff using keys or codes.
1 - 8A
N.C. safety contact on passage compartment side A (internal side of automation view). When the door is closing, opening of the
contact causes movement inversion.
N.B. Connect the safety devices with testing (see 41 terminal) and remove the 41 – 8A jumper.
1 - 8B
N.C. safety contact on passage compartment side B (external side of automation view). When the door is closing, opening of the
contact causes movement inversion.
N.B. Connect the safety devices with testing (see 41 terminal) and remove the 41 – 8B jumper.
1 - 6A
N.C. safety contact in opening side A (left hand side of automation view). When the door is opening, opening the contact causes
slowing of the door in the last 500 mm (the safety function of the 6 terminal can be modified using the advanced parameters menu).
N.B. Connect the safety devices with testing (see 41 terminal) and remove the 41 – 6A jumper.
1 - 6B
N.C. safety contact in opening side B (right hand side of automation view). When the door is opening, opening the contact causes
slowing of the door in the last 500 mm (the safety function of the 6 terminal can be modified using the advanced parameters menu).
N.B. Connect the safety devices with testing (see 41 terminal) and remove the 41 – 6B jumper.
41
Test output (+12V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the following chapters.
N.B. For devices without testing, connect the N.C. contact to the terminals 41 – 8A, or 41 – 8B, or 41 – 6A, or 41 – 6B.
Terminals
Description
MAINS IN
Power cable for automation connection to the electricity mains.
FUSE F1
Mains fuse 5x20 type F3.15A
Electronic control:
MOT
Brushless motor
ENC
Angular sensor
BAT
Battery powered device
FUSE F2
Battery fuse 5x20 type F16A
LK
Locking device
1-S1
Locking signalling device
11