Installation of the locking device

Fasten the locking device to the box profile, using the specific screws.
Fasten the lock coupling bracket on the carriage.
Manually bring the leaf to the closure position and adjust the position of the bracket and/or lock to obtain correct coupling of the locking device.
Connect the locking device to the LK connector of the electronic control, using the cable supplied (the excess part should be shortened). Respect the colours of
the wires (red with red and black with black).
Pass the unlocking cord on the lower part of the left head, until the locking device is reached. Pass the cord through the spring and lock it, rotating it once around
the bracket. With the leaf in the closure position and locked, check that by manually pulling the unlocking cord, the door can be manually opened.
Connect the micro-switch to the electronic control terminals, using cabling supplied (common =1; N.O.=S1).
If you need to pass the unlocking cord in the lower part of the right head, proceed as follows:
- unscrew the 4 lower locking screws,
- turn the lock, bringing the spring to the right,
- fasten the micro-switch on the left,
- screw in the 4 lower screws again.
N.B. Pulling the unlocking cord, the leaves are unlocked, also in the absence of the mains, and remain unlocked up to when electrical power is restored.
6

Installation of battery-powered device

Fasten the battery-powered device on the box profile
Connect the battery-powered device to the BAT connector of the electronic control, using the cable supplied.
Check the battery is connected to the electronic board.
Connect the mains supply automation and wait at least 30 minutes to allow the battery to recharge. Check that by removing mains power, the door opens
automatically.
N.B. to allow recharge, the battery-powered device must always be connected to the electronic control. In the event of long periods of automatic door non-
use, disconnect the battery from the electronic board.
If you want, you can connect a signalling LED for battery presence (not supplied by us), between the terminals [+] and [LD] as indicated in the figure. In the
presence of mains power, the LED flashes for 10 seconds, while in the absence of mains power, the LED stays on.
If you want, you can connect a signalling N.O. contact to re-enable battery operation (e.g. using a key selector, not supplied by us), between the terminals [+]