Manual use of the sliding door

LUCE R automations for automatic sliding doors are extremely reversible and allow manual movement of the leaf without additional forces.
There are mainly two situations in which manual movement is necessary of the door:
- for cleaning operations of the leaves, of the glass and the sliding guides outside the automation;
- in the event of a power failure, or an automation fault.
N.B. In both cases, any bolts or locks should be opened on the leaves.
9.1 MANUAL USE OF THE SLIDING DOOR FOR LEAF CLEANING OPERATIONS
Manual movement of the sliding leaves is always possible by choosing the open door mode on the functions selector.
N.B. In the absence of the functions selector, you can maintain the door in open door mode
using a switch connected to the 1-KO terminals of the electronic control.
9.2 MANUAL USE OF THE SLIDING DOOR IN A POWER FAILURE OF FAULT
Manual movement of the sliding door is always also possible in a power failure or automation fault.
In the presence of the locking device, pulling the unlocking cord, the doors are unlocked and remain so until electrical operation is restored.
To disconnect mains power, for example in the event of an automation fault, disconnect the plug from the electrical socket positioned near the automation, or
use the omnipolar switch/sectioning device prepared in the electrical system.
10

Use the sliding door for emergency exits (without breakout leaves)

The LUCE R automation is used in emergency exits, and allows automatic opening of the door in the event of a fault, in a power failure, or
signalling by an alarm system.
The door must be equipped with an opening sensor 31RD0002 for emergency exits, installed in the escape direction.
To keep the door closed and disable emergency exit operation, you must install the functions selector 31MP0005.
The functions selector must only be accessible by authorised staff, using a badge.
N.B. On each switch on, or every 24 hours, the emergency opening test is carried out.
When requested, the door must be equipped with an emergency opening device (EOD), installed in an easily identifiable position and acces-
sible in the escape direction.
The emergency opening device allows immediate opening of the door, independent of the position of the functions selector.