Warnings

9.1 ALARMS

Code
Description
W001
Encoder fault
W002
Motor short circuit
W003
Motor control error
W004
Current reading circuits fault
W010
Movement inverted
W011
Stroke too long.
W012
Stroke too short
W013
Beyond stop
W014
Motor absent/faulty
W100
User program not correct, Absent

9.2 EVENTS

Code
Description
W126
Internal error
W128
No mains power supply
W129
No battery
W130
Battery flat
W140
OS safety test failed
W142
CS safety test failed
W145
High motor temperature
W146
Motor overtemperature
W148
Lock overcurrent
W150
Opening obstacle
W151
Closure obstacle
W152
Door locked in closure
W153
Door locked in opening
W160
Communication alarm
W256
Board on
W257
Start software board
W320
Maintenance event
Notes
Encoder faulty The automation blocks
A motor short circuit has been detected. The control blocks movement for 1.5s then tries to
power the motor again
Error on motor control circuit. The automation blocks
Reading the motor currents is not correct. The automation blocks
Movement detected of direction contrary to that set. The automation blocks.
During the acquisition phase, a stroke was detected over the maximum permitted. The
automation blocks
During the acquisition phase, a stroke was detected under the minimum permitted. The
automation blocks
During operation, a stroke was detected longer than that acquired. The automation blocks
Detected in approx. 3s, if the motor was detached or faulty (no current absorption)
Software upgrade unsuccessful or corrupted. Switch off and back on the board (with the
USB pen inserted) to restart the upgrade procedure
Notes
Alarm that groups all the internal test failures of the board
Enabled if an operating mode is set which includes battery presence
Insufficient battery voltage detected
The door stays open
The door stays open
Manoeuvre speed lowered to safe value [15°/s]
Door stopped until the motor temperature returns to safe values
Anomalous lock power supply current (too high)
Obstacle detected during opening manoeuvre. The door stops and closes once the automa-
tic closure time is up
Obstacle detected during closure manoeuvre. The door reopens
Door cannot start opening manoeuvre. The door does not accept commands for 5s
Door cannot start closure manoeuvre. The door does not accept commands for 5s
Communication interrupted between coupled boards or non-coherent roles in the coupled
operating mode (e.g. both automations are selected as INT or EXT in interlocked operation)
Enabled once the automation has executed the specified number of manoeuvres from the
maintenance parameter