Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 161
Display panel (Fig. 8)
A) inner side screen (left)
b) outer side screen (right)
C) inner side position indicator
D) outer side position indicator
E) START button
F) STOP button
G) buttons and indicator lights for select-
ing available functions and programmes
H) button for manual geometric wheel
parameter entry
I) function button
J) enter button
K) indicator lights relative to geometric
wheel parameters
L) imbalance visualisation state indica-
tor light
8
ELECTRICAL
HOOK-UP
On request, the wheel balancer can be set
up by the manufacturer to operate with
the power supply available in the place
of installation. The set-up data for each
machine are given on the machine data
plate and on a special label attached to
the power supply connection cable.
WARNING
Any operations to hook up to the electri-
User manual ProLine 650
cal board of the workshop must only be
carried out by qualified personnel, in
accordance with the regulations of the
current laws, and this is the duty and
responsibility of the customer.
- The electrical hook-up must be performed
according to:
• absorbed power specifications indi-
cated on the machine dataplate;
• the distance between the machine
and the power supply hook-up point,
so that voltage drops under full load
do not exceed 4% (10% during start-
up) compared with the rated voltage
specified on the data plate.
- The operator must:
• fit a power plug on the power supply
lead in compliance with the relevant
safety standards;
• connect the machine to its own electrical
connection fitted with a suitable 30-mA
current sensitive circuit breaker;
• fit fuses to protect the power supply
line, rated as indicated on the general
wiring diagram in this manual;
• a suitable earthing system installed on
the workshop mains line.
- Prevent unauthorised use of the machine,
always disconnect the power supply plug
when the machine is not used (switched
off) for extended periods of time.
- If the machine is connected directly to
the power supply by means of the main
electrical board and without the use of a
plug, install a key-operated switch or suit-
able lock-out device to restrict machine
use exclusively to qualified personnel.
WARNING
For the correct functioning of the machine
it is vital to have a good ground connection.
NEVER connect the machine ground wire
to a gas pipe, water pipe, telephone cable
or any other unsuitable object.
UK
49
Tabla de contenido
loading

Tabla de contenido