Unox ChefTop XVC 055 Manual De Instrucciones página 50

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 226
Gas connections
Gas parameter modify at control panel
Change the gas type setting by entering the 2nd level hidden menu of the oven control panel, as follows:
1. To enter the hidden menu, press simultaneously the
2. Press the
button until the display shows: 12 – FrU – 10:
3. Press the
button until the display shows the GAS parameter
-
-
+
4. Use
buttons to select the correct gas type setting : G20, G25 or G30 (includes G31).
5. Press
button to save the new setting
6. Press
button to exit hidden menu
7. To store the new settings disconnect the oven (unplug it), wait for 10 seconds and then re-connect it
Caution!
After each adjustment to a new type of gas:
Apply a permanent label to the rating plate, specifying the data relating to the new fitting:
Seal the adjusted parts again.
Check the gas circuit for leaks.
Carry out a general operational check.
Check if the pressure outlet of the oven gas valve respects the values indicated in the table below:
p max
GAS
[mbar]
G20
14.2 ± 2%
G25 (G25.1)
21.2 ± 2%
G30 (G31)
26.2 ± 2%
English
-
-
+
buttons for 5 seconds
p min
[mbar]
5
7.5
10
50