- Remove the right side panel by unscrewing the fixing screws
- Disconnect the cables from the power supply unit (part. 26 table A)
- Unhook the power supply unit from the omega bar
- Replace the power supply unit
- Carry out the reverse operation for reassembly.
5.3.9
REPLACING THE FUSE
Once the operations in 5.1 have been carried out to replace the power
supply unit, proceed as follows:
- Remove the right side panel by unscrewing the fixing screws
- Open the door where the fuse is located (Fig.24 part.D)
- Replace the fuse
- Carry out the reverse operation for reassembly.
5.3.10
REPLACEMENT OF THR THERMOCOUPLE
Carry out the operations in point 5.1, to replace the thermocouple
proceed as follows:
- Remove the right side panel by unscrewing the fixing screws;
- Remove the inner casing and the insulating rock wool;
- Unscrew the fixing nut of the thermocouple;
- Disconnect the two thermocouple power cables (detail 22, table A);
- Replace the thermocouple;
- Carry out the reverse operations for reassembly, making sure to connect
the connectors according to the correct polarity.
5.4
DISPOSAL
When the appliance or its spare parts are dismantled, the various
components must be sorted out by type of material and disposed of in
compliance with current local laws and regulations.
The presence of a wheeled dustbin with a crossed-out
line through it indicates that within the European
Union electrical components are subject to special
collection at the end of their working life. In addition
to this provision this regulation applies to all its
accessories if marked with this symbol. Do not dispose
these products as normal urban waste
6
LIST OF SPARE PARTS
Index of the Tables
Tab. A
CORE - Assembly
Tab. B
CORE - Wiring diagram
INSTRUCTIONS FOR ORDERING SPARE PARTS
Orders for spare parts must contain the following information:
- Appliance type
- Appliance serial number
- Name of part
- Required number
UK/8