Then insert a flat item of laundry around the roller for the duration of the extended
•
shutdown.
Paraffin block reference: 12156317
When the machine is restarted after a prolonged stoppage, the paraffin evaporates naturally
at high temperature. However, it is preferable to pass a few worn flat cloths through before
starting normal production in order to remove all the paraffin.
4.4 Feeler checking and cleaning
The machine has 2 feelers placed against the cylinder and located under the infeed table, in
which the 2 temperature sensors and the safety thermostat that are used to regulate and
secure the cylinder temperature are housed. The sensor position must be checked before each
start-up (machine cold) and they must be cleaned (lint) regularly (see section 6).
Side view
Infeed table
Feeler in the wrong position
Feeler in the correct position
Cylinder
Removal blade
19