Fagor PS-20/140 M Manual De Instrucciones página 17

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
Motor power (KW)
Heating power (KW)
Total power (KW)
Protection (A)
Cable size
(mm²)
2.2.6 Vapour evacuation connection
The vapour extraction connection to the outside is mandatory (the duct is not supplied).
Evacuated air must be ducted outside the workplace and must never be connected to other
chimneys which are already used to extract smoke from other equipment.
The location of these ducts must be within the limits defined by environmental thermal
legislation. The pipe used must be rigid and metallic and should withstand temperature
(150°C) and must never pass too close to flammable materials or materials likely to be warped
or buckled by excess temperature.
The inside of the pipe must be smooth so as not to disturb the air trajectory or contain
elements on which lint can accumulate (screws, rivets, etc...).
Inspection hatches in the ducts are recommended to facilitate regular duct cleaning.
Electric specifications
PS-20/140 M
Supply voltage
400V 3P + N + E
230V 3P + E
400V 3P + N + E
5G4mm2
230V 3P + E
4G6mm²
Connection size Ø83 mm
(on the top)
PS-20/160 M
0.37
0.37
10.5
12
10.87
12.37
20
20
32
40
5G4mm2
4G10mm2
PS-20/200 M
0.37
18
18.37
32
50
5G6mm2
4G10mm2
11
loading

Este manual también es adecuado para:

Ps-20/160 mPs-20/200 m