By pressing one of the two speed buttons (2 and 3), the speed changes in steps of 0.5 m/min
from 1.5 to 6 m/min.
By pressing one of the two temperature setting buttons (4 and 5), the display will show
"TEMPERATURE SET" and the set temperature which can be adjusted from 1°C to 180°C.
After adjusting the set temperature, press the validation button (6) to validate the set
temperature and return to the run screen.
When the unit is stopped, the run mode can be selected by pressing the temperature control
arrows (4 and 5):
- Manual mode: the operator sets the ironing speed
- Automatic mode: the speed is adapted according to the evolution of the temperature
(e.g. depending on the load, the speed decreases if the temperature drops rapidly).
By pressing STOP, the programme switches to the cooling phase (if the cylinder temperature
is above 80°C) and the machine will stop automatically when the temperature has reached
80°C.
It is possible to restart at any time during the cooling phase.
If the cylinder temperature is below 80°C, by pressing "START-STOP" (1) the machine stops
instantly without a cooling phase.
3.4
Maintenance Menu
The maintenance menu is used to adjust certain parameters related to machine operation.
To access the maintenance menu, with the machine stopped, press the maintenance menu
access button (7) to display "ENTER CODE - 0000" on the screen. Enter code "1111" using
the "temperature increase" buttons (4) to select the 1st digit (between 0 and 9) and the
"validation button" (6) to validate and go to the
List of parameters:
The values can be modified using buttons 4 and 5 and confirmed by pressing the validation
button (6).
- MAX TEMP: Maximum set point temperature corresponding to the maximum set point
temperature adjustable by the user. Adjustable from 100°C to 180°C (default value =
180°C)
- PREHEATING: Preheating temperature adjustable from 20°C to 180°C (default value
= 130°C).
- COOL DOWN TEMP: Cooling temperature at which the machine automatically stops.
Adjustable from 60°C to 105°C (default value = 80°C)
- PREVENTIVE MAINTENANCE: It is possible to program a time in hours and when this
operating time is reached, a message appears each time the machine is switched on
(default value = 0, no message) in order to plan a complete machine maintenance (see
section 6).
The message can be reset in the statistics menu (see section 3.5).
3.5
Statistics menu
The statistics menu is used to view some of the machine's statistics and to reset the
maintenance counter.
digit and so on.
2nd
15