Dometic WAECO CoolAir SP-900 Instrucciones De Instalación página 43

Equipo de aire acondicionado split para camiones
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
SP-900-Install.book Seite 43 Montag, 25. Januar 2010 4:53 16
CoolAir
6
Configuration
Before you first start up the system, you can adapt the controls according
to the installation conditions. This must be done by the person installing
the system.
In configuration mode, the following system software parameters must be
set at the control panel (see Fig. 18 on page 10).
Menu
level
1
2
3
4
Configuration mode can still be activated if the undervoltage
protection mechanism has switched off the system and only residual
voltage is available.
6.1
Starting and ending configuration mode
The adjustable parameters can be changed in configuration mode:
➤ With the system switched off, press the ON/OFF button (fig. 18, 6)
➤ Within these 2-4 seconds, also press the Mode + button (fig. 18, 8).
➤ Release the ON/OFF button.
➤ Keep the Mode button pressed until the compressor LED flashes.
✓ You are now in configuration mode.
✓ The first digit of the display (fig. 18, 9) shows the menu level and the
If you make no entry on the control panel for 60 seconds, the system quits
configuration mode and the system shuts down.
➤ Press the ON/OFF button (fig. 18, 6) to quit configuration mode.
Parameter
Meaning
Set temperature The system starts at the tempera-
ture defined here.
Low voltage
The battery monitor shuts down the
shutdown
system at the voltage defined here.
Operating mode The system starts with the operat-
ing mode defined here.
Default settings Parameters 1-3 can be reset to the
default settings.
I
and keep it pressed for 2-4 seconds.
second and third show the parameter which can be set, e.g.
menu level 1 and a set value of 18 °C.
I
Configuration
Default
setting
20 °C
Character-
istic figure 4
= 23.5 V
0 =
Automatic
mode
--
1.18
for
43
loading