14.3 Electrical connection
Dangerous electrical voltage!
 The machine may only be connected to the mains supply and the associated
checks carried out by a qualified electrician or under the instruction and
supervision of a qualified electrician!
Check, whether the neutral connection function properly.
Check, whether the supply voltage and the frequency correspond to the specifications of
the machine.
Deviation of the supply voltage and frequency!
A deviation from the value of the supply voltage of ±5 % is permissible.
A short-circuit fuse must be provided in the power supply system of the machine!
Use a supply cable that fulfils the electrical requirements (e.g. H07RN, H05RN) and take the
required cross-section of the supply cable from a current carrying capacity table. Pay
attention to the measures for protection against mechanical damage.
Make sure that the mains connection is fused with a maximum of 16 A.
When using an extension cable, make sure that the dimension matches the connected
load of the machine. The connection power can be found in the technical data, the
correlation of cable cross-section and cable lengths can be found in the technical literature
or obtain information from a specialist electrician.
A damaged cable must be replaced immediately.
14.4 Connection to a dust collection system system
The machine must be connected to a dust collection system for dust and chips. The dust collection
system must start up at the same time as the machine's engine. The air speed at the suction
connection and in the exhaust air lines must be at least 20 m/s for materials with a moisture <12 %
(at least 28 m/s for moist chips with a moisture >12 %). The hoses used must be flame-retardant
(DIN4102 B1) and permanently antistatic (or earthed on both sides) and comply with the relevant
safety regulations. For information on air volume flow, negative pressure and suction connection,
please refer to the technical specifications.
14.5 Settings
Danger due to electrical voltage!
Handling the machine while it is connected to the voltage source can lead to serious
injuries or death.
 Always disconnect the machine from the voltage source before carrying out
adjustment or maintenance work and secure it against reconnection.
Saw blade
The material of the workpiece and the saw blade teeth are important criteria for a precise cutting
result. Both the number of teeth and their shape, arrangement and position are associated with a
specific function.
To improve the quality of the cut, always make sure that several teeth (at least 2-3) cut through the
workpiece at the same time. If only one tooth is working, the result is a poor machining surface
and the risk of kickback, vibrations and sound pollution increase.