OPERATION
3. Push and hold the STOP button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
4. Push and hold the START button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
5. Push the Pairing button on the side of the control panel
until the START/STOP button illumination turns OFF.
Release the button.
6. Turn the generator battery switch to the OFF position.
The remote is now paired.
STARTING THE ENGINE
Fire and explosion hazard. DO NOT add gasoline to the
fuel tank while the generator is in operation.
During Push-Button or Remote Start the engine will
automatically set the choke and begin the start sequence.
If the engine fails to start, the generator will attempt to
start the engine two more times. The battery switch can be
turned off at any time during the automatic start sequence
to abort the engine start attempt.
If the cranking speed drops after each unsuccessful
attempt, then the battery may not be adequately charged.
See BATTERY MAINTENANCE
1. Verify that fuel is in the gas tank.
2. Turn the fuel selector switch to gasoline operation.
3. Turn the fuel valve to the ON position.
4. Push the battery switch to the ON position.
5. Choose the starting method:
a. Remote Start: Push and hold the START button on
18 | Westinghouse Outdoor Power Equipment, LLC
section.
the remote start key fob for one second.
Note: Remote start-equipped generators must be restarted
with the START/STOP switch on the control panel
after an automatic shut-down occurs.
b. Push-Button Start: Push and hold the engine
START/STOP button for two seconds.
STOPPING THE ENGINE
1. Turn off and unplug all connected electrical loads.
IMPORTANT: NEVER start or stop the generator with
electrical devices connected.
2. Let the generator run with no load for several minutes to
stabilize internal temperatures of the engine.
3. Turn the engine start switch to the OFF position.
Note: Alternately, if the generator is used infrequently,
turn the fuel valve to the OFF position to limit the
residual fuel remaining in the system. The engine
will stop when fuel in the carburetor and fuel line is
exhausted.
FREQUENCY OF USE
If the generator will be used on an infrequent or intermittent
basis (more than one month before next use), refer to
the Battery Maintenance and Storage sections of this
manual for information regarding battery charging and fuel
deterioration.
AC CIRCUIT BREAKERS
The circuit breakers will automatically switch OFF if there
is a short circuit or a significant overload of the generator
at each receptacle.
If an AC circuit breaker switches OFF automatically,
check that the appliance is working correctly and it does
not exceed the rated load capacity of the circuit before
resetting the AC circuit breaker ON.
The main circuit breaker controls total output of all outlets to
protect the generator from overload or short circuit.