Main databank data display

Displaying the data for the selected vehicle from
the main databank.
copies the vehicle's data into a new user
databank record and opens it in modify mode.

Password input window

To access select the
icons.
In the relative fields, enter the old password and
the new one, which you will have to type in again
to check that it is correct.

Vehicle make records

To access select the
icons.
Locate the cursor on the record of the make
and select it with ↵ to display and/or modify
its contents.
The fields highlighted in blue are compulsory.
during vehicle selection, identifies the
new makes entered by the user, not accompanied
by the specific graphic logo.

MEAsURInG sITE CHECK

Lift check and sensor calibration utility. The
procedures are enabled automatically when the
wheel aligner is switched on if the "Yes" option
is selected for the "Alignment procedure cus-
tomisation - Lift test" field in the user setup.
If the procedure is enabled, the wheel aligner
will recall the lift check screen whenever it is
switched on. The procedure can also be recalled
from the initial screen using the
icons.
Operator's Manual EXACT 7000
Do not use the check procedure to
This tool allows checking of the mechanical stabil-
ity of the lift used for the wheel alignment check.
The lift check function can only be used on lifts
fitted with clamps for the alignment sensors.
For the initial check and whenever you wish to
,
and
reset the system, proceed as follows:
1) With the lift lowered, fit the sensors into the
2) level the sensors with the aid of a spirit
3) save the sensor values, which will be used
,
and
For daily checks, use only points 1 and 2 of the
complete procedure.
If the lift fails to pass the test, there may have
been mechanical changes in the lift (check that
the lift is level) or the sensors may no longer be
properly calibrated (check the sensor calibration
by recalling the relative procedure).
log contains the date when the data were saved,
the operator and any working notes.
sensor calibration check (fig. 50)
Procedure which allows you to check that the
sensors are correctly calibrated.
check screen.
Proceed as follows:
1) drive the vehicle onto the lift, positioning
2) fit the brake pedal clamp;
3) remove the safety pins from the turntables
and
4) fit the sensors on the wheels, fitting the front
5) SET THE THRUST ANGLE AT ZERO using
Lift check – MKs –
(Fig. 48)
WARnInG
level the lift.
clamps provided on the lift;
level;
for subsequent checks. The default password
is "mercedes". You will be prompted to pro-
vide the operator's name and any working
notes.
records the saved data log (fig.49). The
recalls the procedure from the lift
the wheels straight on the turntables and
slip plates;
and slip plates;
sensors on the rear axle and vice-versa;
the steering wheel and then fit the steering
wheel clamp. When the values measured are
GB
81