Coin calibration (fig. 17)
1. Coin designation
2. Calibrated channel
3. Reference channel
4. Value
5. Coin counter
6. "Save" button
Using the "Open" button customer configurations
that have already been saved can be loaded.
-
Enter designation of coin.
(e.g. coin dimensions)
-
Set the freely chosen channel "16".
-
Enter the value "1".
-
Enter the reference channel with the same desired value "2".
-
Insert at least 10 different coins slowly and at the same time
pay attention to coin counter (if coin has been counted up).
Recommendation: Insert in 30 different coins.
-
Click "Save" button to save data.
-
Check the checkmarks entered.
The software asks if it is desired to calibrate another channel
(fig. 18)
-
If it is not desired to calibrate another channel, press the "NO"
key to save the data and exit the page.
Confirm by selecting the "OK" key (fig. 19).
The home screen is displayed (fig. 15).
-
Click on the "Configuration" key (fig. 20).
The screen shown in figure "21" is displayed.
1. Identification
(e.g. Enter customer name)
2. "Read"
(Input data can be read out)
3. Write
(Coin acceptor is described)
4. "Open"
(Save a previously saved record to coin acceptor)
5. "Save"
(Saves new record in program database)
6. "Description
(Free text input, e.g. coin size 26/6 x 2.3)
7. "Price" field
Credit Price - Pulse width in "ms" (Pulse amplitude in "ms")
8. Type of coin
(Holed tokens/coins)
9. "Exit" button.
-
Insert, for instance, the customer's name in the "Identification"
field.
-
Insert the checkmark next to the "Holed tokens/coins" field.
-
In the "Credit price" field, enter the value 1.0.
-
In the "Pulse width" field, enter the value 60.
-
Confirm by pressing the "Write" key (the data are transferred
to the coin/token device).
-
Click on "Exit" to close the program.
-
Perform a test to check correct operation.
Programming via the DIP switches is no longer
necessary / possible.
13.b - PROGRAMMING COINS WITH DIP
SWITCHES
"Figure 13"
-
Open the right door (4) of the machine.
-
Rotate the power switch (14) to "OFF"
-
Pull to you the coin/token device module (52) to release it from
the base.
"Figure 22"
-
Turn all the dip-switches to "ON" position.
-
Reposition the module (52) on the coin/token device base,
assuring that it's correctly placed.
-
Rotate the power switch (14) to "ON".
Insert 15 tokens or coins of the same type
(x)
in the coin/token device slot.
"Figure 23"
-
Wait for the programming end "double clack".
-
Pull to you the coin/token device module (52) to release it from
the base.
-
Turn all the dip-switches in "OFF" position.
-
Reposition the module (52) on the coin/token device base,
assuring that it's correctly placed.
-
Turn the general switch (14) on "OFF" then bring it back on
"ON".
-
Move the dip-switches from 1 to 5 in "ON" position.
-
Under this condition, the coin/token device ONLY accepts the
type of coin or token previously used (see note "x").
-
If you desire to enable coins too (€ 0,20, € 0,50, € 1,00, € 2,00),
move the corresponding dip-switch to "OFF".
Example (fig. 24):
to enable the acceptance of tokens and 0,50 € and 1,00
€ coins, move the dip-switches ....
1 >
ON (disabled)
2 >
OFF (enabled)
3 >
OFF (enabled)
4 >
ON (disabled)
5 >
ON (disabled)
OFF (enabled)
6 >
-
Reposition the module (52) on the coin/token device base,
assuring that it's correctly placed.
-
Close the right door (4).
It is possible to program the coin/token device also for other
functions, but only using a software. In this case is needed to
download the software from
"www.comesterogroup.com"
and purchase the specific tools (see fig.14) to connect to the coin/
token device.
14.
CYCLE TIMES SETTING
-
It's possible to modify the cycle duration of every single function,
operating on the respective regulator.
-
Regulator "PI" always refers to brush operation.
Minimum 30 seconds - Maximum 7 minutes
a. Open the right door (4).
b. Turn the regulator as desired
(fig.25)