Maintenance
6.1.c - Planned maintenance
6.1.c.a - Every 600 hours a careful chamber cleaning
(Fig 2)
Make sure the oven is totally cool, then open the door,
remove the protection (1) unscrewing the relevant
screws and gently take off the refractory surface (2)
from the door. Remove all possible residues by a
vacuum cleaner.
Clean the fi reproof surface by utilizing the special
brush.
ATTENTION
Carefully handle the refractory surface.
DO NOT wash with water, DO NOT wash in a dish-
washer, DO NOT utilize detergents to clean the
refractory surfaces, only use a wet cloth.
6.1.c.b - Every 2 years
Contact manufacturer's technical service to carry out
a comprehensive checking of the oven.
6.1.d - Maintenance in case of need
6.1.d.a - Lamp holder replacement (Fig 3)
This operation shall be carried out by a skilled
technician.
Remove the left-hand panel (1).
Unscrew both screws (2) and remove the square.
Remove the lamp and release the lamp holder by
operating the spring (3).
Replace the lamp holder and reassemble all by pro-
ceeding in the opposite way.
DANGER
FIG. 2
FIG. 3
1
2
2
3
GB - 23