ROBO Compact W500 / W600
9.4 Cleaning the cable assembly
WARNING
Risk of injury
Serious injuries may be caused by parts swirling around.
• When cleaning with compressed air, wear suitable protective clothing, in particular safety
goggles.
NOTICE
• Replace any damaged, deformed or worn parts.
Figure 8 below is based on cable assembly connectors Euro CC and RPC. The Euro CC version
is shown.
Carry out each step in accordance with the figures below:
Fig. 8
1 Loosen the cable assembly and lay it out straight.
2 Clean the wire conduit from both sides with compressed air.
3 Mount all components in reverse order.
D
Cleaning the cable assembly
9 Maintenance and cleaning
A
B
C
EN - 21