PP Plus 36D/240D/401D
4.5 Attaching the cable assembly on the machine side
1 Join central connector and central socket at the wire feed unit and secure them with the
connection nut.
2 Properly mount the connections for water supply/return, shielding gas and control lead plug.
4.6 Connecting the coolant
WARNING
Risk of burns
The cable assembly overheats if the coolant level is too low.
• Wear the correct protective gloves.
• Check the coolant level at regular intervals.
NOTICE
• Make sure that the coolant supply and return have been installed properly.
Coolant supply = blue, Coolant return = red.
• Do not use any deionized or demineralized water as coolant or for tightness or flow tests.
This may impair the service life of your welding torch.
• For liquid-cooled PP Plus welding torches, we recommend using the ABICOR BINZEL
coolant of the BTC series.
Please consult the applicable safety data sheet.
• Each time the device is commissioned or after each cable assembly change, the cooling
system must be purged of any air: Disconnect the coolant return hose from the re-
circulating cooling unit and hold it over a collecting device. Close opening at the coolant
return. Open it again by repeatedly and abruptly releasing it, until the coolant is flowing
continuously and without air bubbles.
BAL.0140 • 2018-10-15
4 Putting into operation
EN - 11