9.1 Maintenance intervals
NOTICE
• The specified maintenance intervals are standard values and refer to single-shift
operation.
When using arc welding equipment, always observe the provisions of EN 60974-4 Inspection
and testing, as well as any national laws and regulations.
Check the following:
Several times a day
Clean weld spatter from the torch
head. In the case of heavy weld
spatter build-up, clean during
each welding break.
• Clean the ROBO Compact
W500 / W600 using
a ABICOR BINZEL torch
cleaning station then spray it
with ABICOR BINZEL anti-
spatter fluid.
Tab. 9
Maintenance and cleaning
9.2 Wire guide
Consult the product information in the instruction leaflets provided each time the wire guide is
changed (spiral liner/PA liner).
9.3 Replacing wear parts
NOTICE
• Use only original ABICOR BINZEL wear parts.
• Use the ABICOR BINZEL switch key wrench to mount and detach the wear parts,
and make sure that the connections are properly assigned.
• Use the average tightening torque to tighten the wear parts.
Tab. 10 Tightening torques for wear parts on page EN-20
• Replace any damaged, deformed or worn parts.
• Spray the wear parts with ABICOR BINZEL anti-spatter fluid.
• Test the TCP in the alignment jig after every use or following a collision.
Weekly
We recommend basic cleaning once
a week. The type and frequency of
cleaning shall be determined and
established by the welding system's
operator.
Optional wire brake
• Clean the wire brake 1–2 times
depending on the quality of the
wire
9.5 Cleaning the wire brake
(optional version with wire
brake) on page EN-22
9 Maintenance and cleaning
Monthly
• Check that the
connections (cable
assembly, control lead,
ground) are secure.
Tighten if necessary.
EN - 19