Confirming functionality
After assembling all of the parts, make sure that there are no
parts remaining (except spare screws, washers and nuts) re-
view the entire assembly procedure in this manual to confirm
that the device has been correctly assembled.
If this device has been correctly assembled, follow the proce-
dures in "Basic Operation" (p. 15) to confirm its functionality.
If a problem is found in the assembly or functionality, follow the
troubleshooting procedure that's described below to resolve the
problem.
Assembly troubleshooting
• Extra parts remaining
→ There are more screws, nuts and washers than the number than
needed to complete assembly.
→ If there are any other parts remaining, return to the step where
those parts were used and correctly perform the assembly pro-
cedure.
• Parts missing
→ If any parts are missing, contact your local Korg distributor.
→ If any parts are damaged or missing before beginning the as-
sembly procedure, contact your local Korg distributor.
• Cannot be assembled. Parts are damaged.
→ Contact your local Korg distributor.
• After being assembled, the device is producing a strange
noise when tilted or shaken.
→ There may be a loose screw or some other loose part within the
device. Open the bottom panel and check inside the device.
• The controls or jacks are loose.
→ Remove the knob, and then firmly tighten the nut.
Troubleshooting
If any control does not function even though it has been set, a
cable may have not been correctly connected during assembly.
Check the appropriate cable according to the symptom.
• The device does not turn on.
→ Is the 9-pin red wire harness or 5-pin purple wire harness dis-
connected?
• No sound is produced from the headphones.
→ Is the 13-pin orange wire harness or 11-pin yellow wire harness
disconnected?
• No sound produced when the TRIG SW button is pressed.
→ Is the 2-pin blue wire harness disconnected?
• The device is turned on, but the MODULATION GENERA-
TOR LED does not blink.
→ Is the 15-pin brown wire harness disconnected?
• The controls in the EXTERNAL SIGNAL PROCESSOR
section do not work.
→ Is the 12-pin green wire harness disconnected?