Troubleshooting
Problem
Possible causeV
1.
The unit does
The mains
not start /
switch is in the
does not heat
„O (Off )" posi-
up
tion.
2.
No power
3.
Feed cable not
plugged in
4.
Blocked control
card
5.
Incorrect ther-
mostat setting
6.
Bridging the
temperature
sensor
7.
Fuse damaged
1.
Motor/pump
No fuel
runs but fla-
2.
Ignition device
me does not
is dirty
ignite
3.
Fuel filter is dirty
4.
Nozzle is dirty
5.
Photocell is
dirty, damaged
or improperly
installed
6.
Foreign sub-
stances in the
tank
7.
The electrodes
are worn out
or placed at
an unsuitable
distance
1.
Fan blocks or
Engine dama-
rotates too
ged
slowly
Note
After all troubleshooting, maintenance and cleaning work, wait at least 5 minutes
before switching the unit on again.
If the unit still does not work properly, please contact the customer service or an
authorised electrician. The unit must then be checked and repaired if necessary.
Warranty
The warranty period is 24 months for consumers and begins at the time of purchase
Possible solution
of the appliance.
The warranty only covers defects that are due to material or manufacturing faults.
1.
Turn on the switch „I
When claiming a defect within the meaning of the warranty, the original purchase
(On) „.
receipt with the date of sale must be enclosed.
Improper use, e.g. overloading of the unit, use of force, damage due to external
2.
- Plug the mains cable
influences or foreign bodies, are excluded from the warranty. Non-observance of
into the socket cor-
the operating instructions and normal wear and tear are also excluded from the
rectly
warranty.
- Check the power
supply network.
Important customer information!
3.
Contact the technical
service centre
Please note that a return within or even outside the warranty period should always
be made in the original packaging. This measure effectively avoids unnecessary
4.
- Restart the generator
transport damage and its often contentious settlement. Only in the original box is
- Identify the display
your device optimally protected and thus a smooth processing is ensured.
error
- Contact the technical
Service
service centre
5.
Calibrate the thermos-
Do you have technical questions? A complaint? Do you need spare parts or opera-
tat by setting it higher
ting instructions? On the homepage of the company Güde GmbH & Co KG (www.
than the ambient
guede.com) in the service area we will help you quickly and unbureaucratically.
temperature.
Please help us to help you. In order to be able to identify your unit in the event of
a complaint, we need the serial number as well as the item number and year of
6.
Wait at least ten mi-
manufacture. You will find all these data on the type plate.
nutes and then try to
activate the ignition
Tel.:
again.
Fax:
- Contact the technical
service centre
E-Mail:
7.
Contact the technical
Disposal
service centre
1.
Switch off the unit,
fill the fuel tank and
restart the unit.
Keep packaging parts out of the reach of children and dispose of them as soon as
possible.
2.
Contact the technical
The packaging protects the unit from damage during transport. The packaging
service centre
materials are usually selected according to environmentally compatible and disposal
aspects and are therefore recyclable. Returning the packaging to the material cycle
3.
Clean the filter with
saves raw materials and reduces the amount of waste. Packaging parts (e.g. foils,
clean fuel
Styrofoam®) can be dangerous for children.
4.
Contact the technical
Do not dispose of electrical appliances in household waste, use the collection points
service centre.
in your municipality. Ask your local authority for the locations of the collection
points. If electrical appliances are disposed of in an uncontrolled manner, hazardous
5.
Contact the technical
substances can enter the groundwater and thus the food chain during weathering,
service centre.
or flora and fauna can be poisoned for years. If you replace the appliance with a new
one, the seller is legally obliged to accept the old one for disposal at least free of
6.
Empty the fuel tank
charge.
and fill it with clean
When disposing of the unit, the relevant regulations on the disposal of used oil must
fuel.
be followed.
7.
Contact the technical
service centre.
1.
Contact the technical
service centre
+49 (0) 79 04 / 700-360
+49 (0) 79 04 / 700-51999
Warning Danger of suffocation!
Electrical or electronic equipment that is damaged and/or needs
to be disposed of must be handed in at the recycling points
provided for this purpose.
ENGLISH