DeWalt DXCMLA1683066 Manual De Instrucciones página 16

Idiomas disponibles

Idiomas disponibles

WARNING: Risk of unsafe operation. Unit cycles automatically
when power is on. When performing maintenance, you may be
exposed to voltage sources, compressed air, or moving parts.
Personal injuries can occur. Before performing any maintenance
or repair, disconnect power source from the compressor and
bleed off all air pressure.
To ensure efficient operation and longer life of the air compressor
outfit, a routine maintenance schedule should be prepared and fol-
lowed. The following routine maintenance schedule is geared to an
outfit in a normal working environment operating on a daily basis.
If necessary, the schedule should be modified to suit the condi-
tions under which your compressor is used. The modifications will
depend upon the hours of operation and the working environment.
Compressor outfits in an extremely dirty and/or hostile environment
will require a greater frequency of all maintenance checks.
NOTE: See Operation section for the location of controls.
Checking Safety Valve (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Tubes, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior to
servicing.
WARNING: Risk of bursting. If the safety valve does not work
properly, over-pressurization may occur, causing air tank rupture or
an explosion.
WARNING: Risk from flying objects. Always wear certified
safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3)
with side shields.
Before starting compressor, pull the ring on the safety valve to
make sure that the safety valve operates freely. If the valve is stuck
or does not operate smoothly, it must be replaced with the same
type of valve.
Checking Air Filter (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Tubes, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior to
servicing.
A dirty air filter will not allow the compressor to operate at full
capacity. Keep the air filter clean at all times.
1.
Ensure Auto/Off switch (B) is in the OFF Position.
2.
Allow unit to cool.
3.
Remove the 2 wing nuts (R).
4.
Remove the outer metal covers
(S).
5.
Check the filter elements (T) if
they are dirty or filled with paint,
replace them.
6.
Place the outer metal covers
back over the filter elements.
7. Secure with the wing nuts.
CAUTION: Risk of unsafe operation. Do not operate without air
filter.
Draining Air Tank (Fig. 3)
WARNING: Risk of unsafe operation. Air tanks contain high
pressure air. Keep face and other body parts away from outlet of
drain. Use eye protection [ANSI Z87.1 (CAN/CSA Z94.3)] when
draining as debris can be kicked up into face.
WARNING: Risk from noise. Use ear protection (ANSI S12.6
(S3.19) as air flow noise is loud when draining.
16
R
S
T
loading