Abicor Binzel RAB GRIP Serie Manual De Instrucciones Original página 30

Antorcha con extracción de humos mig/mag
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
1 Identification
Table of contents
1
Identification
1.1
Marking
2
Safety
2.1
Designated use
2.2
Basic safety instructions
2.3
Safety instructions for electrical components
2.4
Safety instructions for welding
2.5
Safety instructions for extraction (according to ISO 21904)EN-31
2.6
Safety instructions for personal protective equipment
2.7
Safety instructions for use
2.8
Classification of the warnings
2.9
Emergency information
3
Product description
3.1
Technical data
3.2
Figures used
4
Putting into operation
4.1
Preparing the welding torch for cable assembly installation EN-33
4.2
Equipping the welding torch
4.3
Connecting the cable assembly, Fig. 1
4.4
Bleeding the coolant circuit, Fig. 2
1
Identification
The RAB GRIP fume extraction torches are
MIG/MAG welding torches for arc welding equipment used in metal inert
gas welding. The devices comply with EN 60974-7 and EN ISO 21904-1
and are not devices that can be used on their own. These operating
1.1
Marking
This product fulfills the requirements that apply to the market to which it has
been introduced.
2
Safety
This chapter describes the essential safety requirements and warns of residual
hazards that should be kept in mind to operate the product safely.
2.1
Designated use
The device described in these operating instructions may be used only for the
purpose and in the manner described in these operating instructions.
The device is used to extract welding fumes and dust that is generated during
welding. The device can be used to extract welding fumes that contain CMR
substances and to extract welding fumes that do not contain CMR
substances. When extracting welding fumes that contain CMR substances,
the welding torch must be operated together with a suitable W3-certified
fume extraction system. Any other use is considered improper. Unauthorized
modifications or changes to enhance the performance are not permitted.
2.2
Basic safety instructions
The product has been developed and manufactured in accordance with
state-of-the-art technology and the recognized safety standards and
directives. Inevitable technical residual risks to the user, third parties, devices,
or other material property are posed by the product. This document
describes the essential safety requirements and warns of residual hazards
that should be kept in mind to operate the product safely. Detailed product
information and product-specific safety instructions are found in the separate
operating instructions and in other product-specific documentation. Non-
observance of the safety instructions may result in risks to the life and health
of personnel, and environmental damage or material damage. The
manufacturer will accept no liability for damage caused by non-observance
of the documentation.
► Before using the system for the first time, please read the provided
documentation carefully.
► Do not operate the product unless it is functioning properly and ensure
compliance with all documents.
► Before carrying out specific work, for example, commissioning,
operation, transport and maintenance, read the documentation
carefully.
EN - 30
4.5
Connecting the extraction hose
4.6
Connecting the shielding gas and setting the gas volume
EN-30
4.7
Feed in wire
EN-30
5
Operation
EN-30
5.1
Operational controls on the handle, Fig. 3
EN-30
5.2
Carrying out the welding process
EN-30
5.3
Regulating the extraction volume, Fig. 3
EN-31
EN-31
6
Decommissioning
EN-31
7
Maintenance and cleaning
EN-31
7.1
Replacing wear parts, Fig. 6
EN-31
7.2
Selecting and attaching the wire guide
EN-32
7.2.1
Shortening and mounting the spiral liner, Fig. 5
7.2.2
Mounting and shortening the PA liner, Fig. 4
EN-32
7.3
Cleaning the cable assembly
EN-32
7.4
Cleaning the welding torch
EN-32
7.5
Annual maintenance by an electrician
8
Disposal
EN-33
9
Warranty
EN-33
EN-33
EN-33
instructions describe the RAB GRIP. They may be operated using original
ABICOR BINZEL spare parts only. The figures show the RAB GRIP 501D
version of the fume extraction torch.
A corresponding marking has been affixed to the product, if required.
Non-observance of the safety instructions may result in risks to the life and
health of personnel, and environmental damage or material damage.
► Do not exceed the maximum load data as defined by the documentation
supplied. Excessive loads lead to irreparable damage.
► Do not make any constructive changes to this product.
► Do not use or store the device outdoors where it is wet.
► During welding work outdoors, use suitable protection against the
weather conditions.
► Use suitable means to protect yourself and bystanders from the hazards
listed in the documentation.
► Store the documentation within easy reach of the device for reference
and enclose all documents when passing on the product.
► Consult the documentation for additional welding components.
► Information about how to handle gas cylinders can be found in the
instructions provided by the gas manufacturer and the relevant local
regulations, e.g., regulations that apply to compressed air.
► Observe the local accident prevention regulations.
► Only trained specialists should commission, operate, and service the
device. Qualified personnel are persons who, based on their special
training, knowledge, experience and due to their knowledge of the
relevant standards, are able to assess the tasks assigned to them and
identify possible dangers.
► Keep the work area in order. Ensure good lighting of the work area.
► Switch off the power supply, gas supply, and compressed air supply,
and disconnect the mains connection for the entire duration of
maintenance, commissioning, and repair activities.
► For disposal, observe the local regulations, laws, provisions, standards
and directives.
RAB GRIP
EN-33
EN-33
EN-33
EN-34
EN-34
EN-34
EN-34
EN-34
EN-34
EN-34
EN-34
EN-34
EN-35
EN-35
EN-35
EN-35
EN-35
EN-35
loading