4. Set the communication channel on the transmitter:
a. Connect the Pulsar Interface Adapter to the communication connector and switch on the communication mode.
®
b. Connect the HART
c. Establish the communication on the HART
d. In the main menu, select 3 / Device Info & Config.
e. In the 3 / Device Info & Config menu, select 1 Channel.
f. Enter the communication channel.
g. Transfer the configuration change to the transmitter.
®
h. Exit the HART
application.
5. Set the same communication channel on the receiver:
a. Connect the Pulsar Interface Adapter to the communication connector and switch on the communication mode.
®
b. Connect the HART
c. Establish the communication on the HART
d. In the main menu, select 4 / Meas. Config.
e. In the 4 / Meas. Config menu, select 1 Channel.
f. Enter the communication channel.
g. Transfer the configuration change to the receiver.
6. Prepare the alignment of both transmitter and receiver. To do this, carry out the following steps on the receiver:
®
a. On the HART
handheld terminal, select 5 / Maintenance in the main menu.
b. In the 5 / Maintenance menu, select 1 Start alignment.
Next to 3 Alignment Mode, Active must be displayed.
The maintenance signal is transmitted on the 4 to 20 mA interface.
The green LEDs flash on the transmitter and receiver.
c. In the 5 / Maintenance menu, select 4 Graphical alignment.
Select 1 Alignment graph.
A crosshair and the signal strength
TX S:
0
The measuring points for both transmitter
have been set to alignment mode. If no DIGITAL LINK connection is present, the transmitter must be set to alignment mode
separately.
18
handheld terminal to the Pulsar Interface Adapter.
®
handheld terminal via the Device Description.
handheld terminal to the Pulsar Interface Adapter.
®
handheld terminal via the Device Description.
are shown on the display:
0
RX
and receiver
TX L:
0
TX
Signal
are only displayed when both transmitter and receiver
0
04633451