Description
Dip status
Dip 1
Dip 2
OFF
OFF
Dip 1
Dip 2
Input mode TD
ON
OFF
(dynamic button - step
Dip 1
Dip 2
by step) and radio CH1
OFF
ON
Dip 1
Dip 2
ON
ON
Dip 3
Dip 4
OFF
OFF
Dip 3
Dip 4
ON
OFF
Barrier speed
(SNAPS - SNAPL)
Dip 3
Dip 4
OFF
ON
Dip 3
Dip 4
ON
ON
Dip 5
OFF
Preflashing
Dip 5
ON
Dip 6
OFF
Reclosing timer
Dip 6
ON
Dip 7
OFF
Boom opening direction
Dip 7
ON
Dip 8
OFF
Slave function
Dip 8
ON
Dip 9
Dip 10
OFF
OFF
Dip 9
Dip 10
US1 output (multifunc-
ON
OFF
tion mode)
Dip 9
Dip 10
potential free contact
OFF
ON
Dip 9
Dip 10
ON
ON
Dip 11
OFF
Opening during black-
outs
Dip 11
ON
Dip 12
Closing after a
OFF
photoelectric cell
Dip 12
intervenes
ON
Description
Dip status
Dip 1
OFF
FT photoelectric cell
input control
Dip 1
ON
Dip 2
OFF
TB stop button
input control
Dip 2
ON
Dip 3
OFF
CC safety edge input
excluded
Dip 3
ON
Dip 4
OFF
TPR power failure
indication
Dip 4
ON
DS1 FUNCTION SELECTION DIP-SWITCH SETTINGS
Function
During opening, press the TD button to stop the barrier; press again to close.
Open-Stop-Close
During closing, press the TD button to stop the barrier; press again to open.
If the TD button is pressed during opening, the barrier stops then closes.
Open-Close
If TD is pressed during closing, the barrier stops then opens.
Pressing the TD button during opening has no effect. Pressing the TD button during a pause has no effect.
Always opens
If the TD button is pressed during closing, the barrier stops for a few seconds then opens.
Open-Close with no
Pressing the TD button during opening has no effect. If the TD button is pressed during a pause, the barrier
inversion during opening
closes. if the TD button is pressed during closing, the barrier stops for a few seconds then opens.
High speed
Opening time approximately 3 seconds
Medium high speed
Opening time approximately 4 seconds
Medium low speed
Opening time approximately 6 seconds
Low speed
Opening time approximately 8 seconds
-
Excluded
The warning light operates together with the motor.
-
Enabled
The warning light operates 5 seconds before any movement.
-
Excluded
After complete opening, the barrier can only be closed by a manual command.
-
Enabled
After complete opening, the barrier closes after the programmed pause time.
-
Left-hand opening
The ECU initial programming procedure must be carried out see page 12.
-
Right-hand opening
The ECU initial programming procedure must be carried out see page 12.
-
Excluded
-
-
Enabled
The control unit performs the commands received from the MASTER control unit
Courtesy light contact
Lit from the beginning of the work cycle until a programmed time after closing.
Warning light contact
Contact for controlling a 2 Hz warning light
Suction cup contact
Active output during opening, closing and pause
Barrier status contact
This output is active when the boom is not closed
-
Excluded
-
-
Enabled
The boom remains open during blackouts. The boom closes when power returns if dip 6 is set to ON.
-
Excluded
-
-
Enabled
Tripping of the photocell reduces the pause time to 2 seconds, regardless of the pause time setting.
DS2 FUNCTION SELECTION DIP-SWITCHES
Function
-
Active
FT input active (a photoelectric cell must be wired to the contacts 18-20).
-
Excluded
FT input excluded (the contacts 18-20 do not need to be bridged).
-
Active
TB input active (a stop button must be wired to the contacts 18-20).
-
Excluded
TB input excluded (the contacts 17-20 do not need to be bridged).
-
Active
CC input active (8,2K contact with jumper J4 in pos. 1 - NC contact with jumper J4 in pos. 1
-
Excluded
CC input excluded (the contacts 16-20 do not need to be bridged).
Connect transformer secondary to binding posts 1 and 2. If mains power fails the boom will open (with dip 11
-
Enabled
set to ON and optional buffer batteries installed).
-
Excluded
TPR input excluded (the contacts 1-2 do not need to be bridged).
Notes
Notes