CONNECTING SENSORS
Note: All sensor harness wires are coded WHITE (POS+) and BLACK (NEG-). Each
sensor must be connected correctly or the DAS will not function correctly.
1.
Locate the Sensor Interconnect Harness in the evaporator.
2.
Unplug the connector from the harness.
3.
Carefully remove orange end from connector.
4.
Remove only the plugs from the connector holes for the sensors you are connecting.
Unused holes must remain plugged.
SENSOR
1
2
3
4
5
6
5.
Insert WHITE (POS+) pin connector and wire into correct connection until it locks
into position (Detail I). The wire side of the connector is shown.
SENSOR
1
2
3
4
5
6
Connecting the Sensors
PLUGS
#1 and #12
#2 and #11
#3 and #10
#4 and #9
#5 and #8
#6 and #7
PLUGS
White into #1
White into #2
White into #3
White into #4
White into #5
White into #6
6.
Insert BLACK (NEG-) pin connector and wire into correct connection until it locks
into position (Detail I). The wire side of the connector is shown.
SENSOR
1
2
3
4
5
6
Reinstall orange end (3) back onto connector (2), apply a light coating of Superlube
to electrical connections and plug sensor back into mating connector on the Sensor
Interconnect Harness (1).
7.
Apply a light coating of Superlube to electrical connections and plug each sensor
into correct mating connector.
8.
Secure sensor with appropriate clamps.
Eng
PLUGS
Black into #12
Black into #11
Black into #10
Black into #9
Black into #8
Black into #7
81