12. Maintenance

12.1

Cleaning and servicing

!
Before cleaning and servicing, switch off
SBM 55S NW and disconnect mains plug.
!
Do not use any solvent-based cleaning agents. Use
alcohol or similar cleaning agents for plastic parts.
The following work is essential to ensure proper opera-
tion and high performance of the SBM 55S NW:
Servicing
Clean moving mechanical parts, treat with spray oil
or kerosene and lubricate with engine oil or a suita-
ble grease.
Calibrating the electronic vernier caliper
Flange calibration.
SBM 55S NW calibration.
Perform reference measurement.
i
Calibration is described in Section 12.3
i
As part of service and upkeep (every six months),
on flange replacement or in the event of measure-
ment inaccuracies, it is advisable to calibrate the
SBM 55S NW in the following sequence.
12.2

Spare and wearing parts

The manufacturer cannot accept any liability for
damage arising from the use of non-genuine replace-
ment parts.
Designation
Standard centering flange
Centering cone 42 - 65 mm
Centering cone 54 - 80 mm
Centering cone 75 - 110 mm
Weight pliers
Manual vernier caliper
Test clip
Calibration weight
Calibration weight (calibrated)
Voltage sticker V 230
Voltage sticker V 110
Direction of wheel rotation sticker
Tab. 2:
Spare and wearing parts
Sicam srl società unipersonale
12.3
i
As part of service and upkeep (every six months),
on flange replacement or in the event of measure-
ment inaccuracies, it is advisable to calibrate the
SBM 55S NW in the following sequence:
1. Flange calibration.
2. Vernier caliper calibration.
3. SBM 55S NW calibration.
4. Perform reference measurement.
12.3.1
i
In the following description the audio is activated.
1. Press and hold the <MENU> key.
2. As soon as CAL appears on the left-hand display,
release the <MENU> key.
x
3. Press the <mm/inch> key within 1.5 seconds.
 Left-hand display shows C-1.
x
x
x
12.3.2
x
i
In the following description the audio is activated.
1. Fit the flange (refer to Section 5).
i
Do not clamp the wheel, do not use any clamping
tools.
2. Close the wheel guard.
 Measurement commences.
i
The unbalance measured is stored on completion of
measurement.
 Electronic compensation is provided for any resid-
Order number
1 695 602 400
1 695 632 500
 Left-hand display shows C-2.
1 695 652 862
1 695 605 600
1 695 606 500
1 695 629 400
1 695 602 700
1 695 654 377
1 695 654 376
1 695 101 269
1 695 100 854
1 695 653 878
Maintenance | SBM 55S NW | 55

Calibration

Call-up of calibration menu

Shaft unbalance correction

ual shaft unbalance.
en
|
1 695 656 114
2012-03-28