Hilti DD 350 Manual Del Usuario página 40

Ocultar thumbs Ver también para DD 350:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 92
All manuals and user guides at all-guides.com
2. Connect the vacuum connector on the vacuum base plate to the vacuum pump.
3. Set the drill stand on the vacuum base plate.
4. Use the screw supplied, complete with its washer, to secure the drill stand to the vacuum base plate.
5. Locate the center point of the hole to be drilled.
6. Draw a line approximately 800 mm in the direction in which the core drilling system is to stand.
7. At a distance of 165 mm (6 1/2 inches) from the center point of the hole to be drilled, make a mark on the
800 mm long line.
8. Switch on the vacuum pump and press and hold down the vacuum release valve.
9. Position the drill stand on the work surface.
10. Release the vacuum release valve.
11. Use the leveling screws to level the vacuum base plate.
◁ The needle of the pressure gauge is in the green area.
Note
Do not level the anchor base plate on the vacuum plate.
12. Secure the drill stand for drilling horizontally.
13. Check that the drill stand is secure.
5.1.5 Adjusting the drilling angle when using the drill stand with combination base plate
WARNING
Risk of injury Risk of crushing the fingers in the articulation.
▶ Wear protective gloves.
1. Slacken the screw at the top at the brace and the screw at the bottom at the pivot joint of the rail.
2. Adjust the rail to the desired position.
3. Tighten the screw at the top at the brace and the screw at the bottom at the pivot joint of the rail.
5.1.6 Extending the rail
Note
When starting a hole, use only a core bit or extended core bit with a maximum total length of 650 mm
(25 1/2 in).
A depth gage on the rail can be used as an additional end stop.
After removing the extension rail, reinstall the cover (with integrated end stop) on the drill stand.
Otherwise the safety-relevant end-stop function is not implemented.
1. Remove the cover (with built-in end stop) from the top end of the rail.
2. Install the cover on the extension rail.
3. Insert the cylindrical connector of the extension rail into the end of the rail of the drill stand.
4. Secure the extension rail by turning the eccentric pin.
5.1.7 Installing the spacer
WARNING
Risk of injury. The fastening may become overloaded.
▶ When one or more spacers are used, the contact pressure must be reduced in order to avoid
overloading the fastening.
Note
When core bits of diameter > 300 mm (11 1/2 in) are used, the distance between drill stand and
drilling axis has to be increased by installing one or two spacers. The hole center indicator is no longer
functional when spacers are used.
Insert the spacer or spacers without the diamond core drilling machine mounted on the drill stand.
1. Lock the carriage on the rail with the carriage lock.
2. Pull out the eccentric pin for locking the diamond core drilling machine on the carriage.
30
English
Printed: 02.11.2017 | Doc-Nr: PUB / 5145256 / 000 / 04
9
10
8
Tabla de contenido
loading

Tabla de contenido