D
V
ESCRIPTION OF THE
ITALOGRAPH
The Vitalograph 2120 is designed for lung function testing not
only in the doctor's office or laboratory, but also for testing
subjects on location, e.g. in hospital wards, factory floors,
office buildings and private homes. All test data is
automatically stored for later retrieval.
M
C
AIN
OMPONENTS OF THE
A
Display
B
Escape button
C
Delete button
D
Enter button
E
Up button
F
Down button
G
On/Off switch
H
Cradle portion
I
Docking area
F
V
EATURES OF THE
ITALOGRAPH
The Vitalograph 2120's features include:
•
rechargeable battery sufficient for a full day's testing
•
performs FVC and VC pre- and post-bronchodilator
tests
•
a communications cradle which also charges the
battery
•
database of subject information
•
test results are time and date stamped
•
stores over 100 tests
•
audio feedback assists test quality
•
retrieve data via printer or PC
•
smart option can automate actions by bypassing the
menus
•
on screen battery low indicator
•
perform real-time testing with Spirotrac PC based
spirometry system connecting through the cradle.
•
uploading subjects from Spirotrac to 2120 through the
cradle
•
download test data from 2120 to Spirotrac through the
cradle
C
V
ONNECTING THE
ITALOGRAPH
P
S
OWER
OURCE
The Vitalograph 2120 is ready for use after charging it for at
least 16 hours.
Dock the unit in it's cradle, as described below, It is not
necessary to turn on the Vitalograph 2120 when charging.
The cradle must, however, be connected to a power source.
Whenever testing is finished, the unit should be docked for
recharging. If the Vitalograph 2120 is not used over a
prolonged period ie. one month or longer, or if a battery low
indication is given, the unit should be placed on the cradle to
fully charge.
h
Do not leave the hand-held portion in the
cradle when there is no power to the cradle –
this may drain the battery.
1.
Plug the power supply (21001204) into the power input
socket at the back of the cradle as shown above.
2.
Plug the IEC connector end of the power cord into the
PowerSAFE.
3.
Plug the other end of the power cord into your nearest
supply outlet and switch the outlet on.
4
All manuals and user guides at all-guides.com
2120
V
2120
ITALOGRAPH
2120
2120
TO A
Power Output
Serial Port
4.
The cradle will now be capable of supplying low
voltage power to the battery (green LED light).
5.
Simply dock the hand-held portion in the cradle
(Orange LED when charging).
h
If you connect additional equipment (not
produced by Vitalograph) to the serial interface
port, it must conform to VDE0750 Part 1-1
regulations and to your EN specifications, e.g.
EN60950 for data equipment, EN60601 for
medical equipment. Non medical equipment
must be kept outside the patient environment
ie. any area in which intentional or unintentional
contact between the patient and parts of the
system, or some other persons touching parts
of the system, can occur.
Medical Devices may be affected by cellular
telephones and other personal or household
devices not intended for medical facilities. It is
recommended that all equipment used near the
Vitalograph product comply with the medical
electromagnetic compatibility standard and to
check before use that no interference is evident
or possible. If interference is suspected or
possible, switching off the offending device is
the normal solution, as is required in aircraft
and medical facilities.
(Contact your distributor if you have any
queries.)
T
O
V
URNING
N THE
ITALOGRAPH
F
T
IRST
IME
Turn on the Vitalograph 2120 by sliding the switch at the side
of the unit towards the flowhead. The date that the device
was last checked and the memory status are briefly
displayed. Pressing ESC at any time during this screen will
by-pass it.
V i t a l o g r a p h
2 1 / 0 6 / 2 0 0 1
C a l . C h e c k :
2 0 / 0 6 / 0 1
M e m o r y
:
9 0 %
After a few seconds the main menu is displayed as illustrated
below.
>
P A T I E N T
T E S T
P R I N T
P O S T
S
U
V
ETTING
P THE
ITALOGRAPH
There are a number of settings that should be checked before
you use the Vitalograph 2120 for the first time. In particular
check Printer and Time/Date (In Config). You can change
these settings at any time to suit your requirements. This is
achieved by selecting Setup in the main menu. The following
screen is displayed.
S e l e c t
o p t i o n
> S A V E
C O N F I G
I N D I C E S
S M A R T
P R I N T E R
A B O U T
Setting Up SAVE
This is used to define the criteria for saving tests. If ATS or
ERS Best are selected then the best test in a session is
saved. If All is selected then every test in a session is saved.
All saving of results is done automatically. Select Save in the
Setup menu.
S a v e
S e t u p
A T S
B E S T
E R S
B E S T
A L L
2120
FOR THE
2 1 2 0
1 2 : 0 5
u s e d
D E L E T E
S E T U P
V I E W
C A L I B
2120
<