Without System Monitoring; With System Monitoring; Monitoring Of Filling Level - Vogel KFG Serie Instrucciones Para El Manejo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 138

7.3 Without system monitoring

In this mode, the lubrication cycle is controlled only
by the preset values for PAUSE and CONTACT.
Monitoring must be switched off.
COP = OFF
System trouble will not automatically be
recognized and visualized.

7.4 With system monitoring

In this mode, additional monitoring of the system
functions is performed by external switches.
Monitoring can take place for:
the filling level of the lubricant vessel
the function of the progressively-acting distributor
by means of a cycle switch
System trouble will be recognized and
visualized automatically.
Monitoring is switched on. COP = CS

7.5 Monitoring of filling level

If installed, monitoring of the filling level
is active all the time.
If the level in the lubricant vessel falls below the
minimum filling level, the lubrication cycle will stop
and a fault message will be visualized on the
display.
Fig. 14 Fault message
FLL:
Fault Low Level
Retrofitting of a pump set with the
„Filling level monitoring" feature, which
did not have this feature before, is
possible only in the factory. The set needs then
to be sent to the factory.