6.5 Alteration of code
The code preset by the factory is now
deleted and the new code is valid.
Write down the new code and keep it in
a safe place. If the code gets lost, programming
of parameters will not be possible then. The
pump set needs to be sent to the dealer or the
authorized Vogel branch office.
Attention:
Do not enter the digits 321 as the new code.
6.6 Programming ranges
Function
Programming range
Pause time
0.1 h to 99.9 h
Pump operating
time
0,1. min to 99.9 min
Pulses
1 to 999
6.7 Display ranges
Display
Display range
Fault hours
0.1 h to 99,999.9 h
Hours run
0.1 h to 99,999.9 h
Step
Key
1
Press SET
longer than 2s
2
Operate appropriate
key until
3
Press SET shortly
(confirm key)
4
Press SET shortly
(confirm code)
5
Operate appropriate
key until
6
Press SET
shortly until
7
Press SET
longer than 2s
Page 30
Contents
Operating Instructions KFG, KFGS
Display
Display is flashing
Select key number
(setting by factory)
Display is flashing
Code 000
(setting by factory)
Display is flashing
New code
Example: 666
Attention ! Do not enter 321
Confirm new code
New code will be written into the memory and
the display will go off.
Chapter
6