Operating Modes; Timer Operation; Counter Operation; Operation In Machines - Vogel KFG Serie Instrucciones Para El Manejo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 138

7. Operating modes

7.1

Timer operation

Pause and pump operating time are time-
dependent.
Set tPA and tCO in the programming
mode.
The time-dependent, preset values for PAUSE and
CONTACT control the lubrication cycle.
PAUSE:
values in hours
CONTACT: values in minutes

7.2 Counter operation

Pause is dependent on number of pulses
Pump operation is time-dependent
Set cPA and tCO in the programming
mode.
An external pulse generator needs to be
connected as described in Paragraph 3.5,
page 17.
PAUSE:
values in pulses
CONTACT: values in minutes

Operation in machines

A switch is opened and closed in dependence of
mechanical movements, revolutions, etc. When
the preset value of the pulses cPA to be counted
has been reached, lubrication will be released.
Page 31
Contents
Chapter
Operating Instructions KFG, KFGS

Operation in vehicles

only for trailers and semi-trailers
Lubricating operation without system monitoring
COP = OFF
The pump set is not equipped with permanent
power supply.
The pump is electrically connected with
the stop light circuit.
Please observe regional regulations for
installation!
The control device counts the brake signals during
the PAUSE. When the preset value of the pulses
cPA to be counted has been reached, lubrication
will be released.
Braking times of a vehicle are usually smaller than
the set pump operating time tCO (the factory
setting is 4 min).
During the following braking processes the control
device will perform lubricating operations until the
set pump operating time tCO is reached.
After that a new lubrication cycle will start with the
pause cPA.