6. Programming

Programming always starts with
the steps 1 – 2 !
The programming mode can be recognized
by the flashing display.

6.1 Start of programming mode

6.2 Alteration of times for
lubrication interval
Carry out steps 1 to 2 !
Note for step 2:
If the code 000 set by the factory was altered, then
the altered code has to be selected with
the
keys and needs to be confirmed with
the
key.
Step
Key
1
Press SET
longer than 2s
2
Press SET shortly
(confirm code)
3
Press SET shortly
4
5
Press SET shortly,
confirm new value
6
Press SET shortly
7
8
Press SET shortly
9
Press SET
longer than 2s
Page 28
Contents
Operating Instructions KFG, KFGS
Display
000 display is flashing
(code 000 is the setting by the factory)
Automatic display of the first
parameter, i.e. „pause in timer
operation". The „pause" LED is
flashing
Pause time 1 h
(setting by factory)
Set new value
Example: 6.8 h = 6 h 48 min
Display of the next parameter, i.e.
„pump operation time in timer
operation"
The „Contact" LED is flashing
Pump operation time 4 min
(setting by factory)
Set new value
Example: 3 min
Confirm new value
Alterations will be written into the memory and
the display will go off.