Installation - Vogel KFG Serie Instrucciones Para El Manejo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 138

2. Installation

General
The pump sets of the KFG and KFGS series form
part of centralized lubrication systems in vehicles,
machines, and equipment, delivering greases of
up to NLGI Class 2.
The pump sets differ in the size of their lubricant
vessels, in their way of filling up lubricant, as well
as in their control and monitoring of functions.
The installation of function-specific pump elements
allows up to three independent lubricant circuits
to be operated by only one pump set.
(see Chapters 2.2 and 2.3).
Installation
Installation of the pump sets KFG and KFGS shall
be done on a vehicle or machine by means of
3 M8 bolts. The mounting should be in a place
which is protected from outside influence as far as
possible. Any bores required for installation shall
be made according to the following diagram.
A boring jig can be ordered under
article no. 951 -130-115.
Fig. 1 Bores for installation
Page 8
When carrying out boring operations,
mind existing supply lines and other
equipment as well as any further sources
of danger, such as exhaust pipes or moving
parts.
Observe safety distances as well as regional
regulations for installation and accident
prevention.
200 ± 0,4