4.1 The three-digit LED display
In normal operation the display is switched off.
It can be activated by shortly pressing one of the
two push-buttons
. The display shows
current values and preset parameters.
Furthermore, the display serves for user prompting
when operating parameters are programmed.
display
function
t = timer
The control device is working as
PA = Pause
timing pulse generator (TIMER)
and is in the PAUSE mode.
c = COUNTER
The control device is working as
PA = PAUSE
pulse counter (COUNTER) and is
in the PAUSE mode.
t = TIMER
The control device is working as
CO = CONTACT timing pulse generator (TIMER)
and is in the pump operating
period (CONTACT)
c = COUNTER
The control device is working as
CO = CONTACT pulse counter and is in the pump
operating period (CONTACT)
C = cycle
Display of menu start
O = OFF
„monitoring settings"
P = Pressure
Page 21
Next
Chapter
4
Operating Instructions KFG, KFGS
meaning
•
Part of lubrication cycle
•
Input and display values
in hours
•
Part of lubrication cycle
•
The device is counting the
pulses of the external pulse
generator and is comparing
them with the preset values
•
CONTACT = time
while the pump delivers
•
Input and display values
in minutes
•
CONTACT = time
while the pump delivers
•
input and display values in
pulses