The machine is getting clogged.
Probable cause
Excessive volume of gathered crop.
Excessive traveling speed.
Incorrect quantity of rotor knives.
Incorrect mounting of rotor knives. Adjust the correct distribution of knives.
Dull rotor knives.
Dull rotor counter knife.
Weak releasing of chopped crop by the chute.
Probable cause
Tractor below the minimum
recommended power.
Incorrect quantity of rotor knives.
Incorrect mounting of rotor
knives.
Incorrect mounting of rotor knives. Adjust the correct distribution of knives.
Excessive cardan vibration.
Probable cause
Unbalanced cardan.
100
Turn off the tractor and turn the cardan
shaft on the machine rear in reverse,
expelling excess of crop.
Reduce speed.
Install the correct quantity of rotor
knives.
Sharpen the knives.
Turn over the counter knife or replace it.
Use a tractor with the recommended
power..
Install the correct quantity of rotor
knives.
Install the correct quantity of rotor
knives.
Check if the length adjustment was
performed properly.