Cleaners; 1- Changing Or Reversing The Cleaners - Nogueira FTN-1000 Super G2 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6.1- Cleaners

The drums are equipped with 2 cleaners each.
The function of these cleaners is to prevent
the accumulation of material underneath the
drums. Frequently check if the cleaners are in
good condition.
6.1.1- Changing or reversing the
cleaners
The cleaners are reversible, when one side is
worn out, assemble it in the another drum,
using its other side.
Immediately replace worn or damaged
double-sided cleaners.
ATTENTION!
Turn off the tractor and remove
the ignition key before starting
the following procedure.
To change the cleaners (K):
Remove the bolt (N) using an Allen key
1.
of 6 mm;
Insert new cleaner and fix with the bolt
2.
(N).
The use of PPE (suitable gloves and safety
glasses) is mandatory during the above
procedure.
ATTENTION!
K
N
Reverse the drum cleaners
when worn.
Instructions Manual
6. Maintenance
89

Capítulos

Tabla de contenido
loading

Tabla de contenido