Secondary parameters
Main level
Level 1
Extras
10: Compensation
11: Robot interface
12: Torch / aux. drive
Special
Customize settings
functions
(Push Up button S13 and
Wire diameter button
S6 simultaneously for 5
seconds until "Customize
settings" appears on the
display)
Tab. 2:
Menu description
01.21
Level 2
Length
Resistance
Length 10...100 (10)
Resistance (10)
0
=
no Push
Pull
/yes
=/* Lorch PP04W 0.8
/yes
=/* Lorch PP04W 1.0
/yes
=/* Lorch PP04W 1.2
/yes
.
.
.
4-stroke 2 On / Off
(Off = basic setting)
TorchPotPow On / Off
(Off = basic setting
TorchPotArc On / Off
(Off = basic setting
4-stroke TT On / Off
(Off = basic setting
Remote 10V On / Off
(Off = Standard, 0...15V)
MMA with Feed On
Torch-Hold On / Off
(Off )
Job Switch On / Off
(Off )
Min Gas (default 2.0)
909.2599.9-06
Note
The type of compensation mode can be selected here.
Length - direct adjustment of welding cable length.
Resistance - automatic resistance measurement via power
source.
Adjustment of welding cable length.
This improves the welding behaviour with long welding
cables.
The parameter display changes according to the selections
made in menu 10.
Welding circuit resistance calibration.
See „14 Welding circuit resistance measurement" on Page
54.
The parameter display changes according to the selections
made in menu 10.
Menu item only visible with robot interface installed or
LorchNet Connector attached (further information on set-
ting and configuration, see operating manual Device Inter-
face INT or LorchNet Connector)
Push Pull is not active (deactivated)
List of supported torches.
If the "*" character is present for the selected torch, the
torch has not been calibrated.
On the other hand, if the "=" character is displayed, the torch
has already been calibrated.
"/yes" = auxiliary drive present
"/-" = no auxiliary drive present
Menu point only visible when
Push Pull option is installed
Switch between main energy and secondary energy by
briefly pressing the torch button.
If TorchPotPow and TorchPotArc are set to On, the function
TorchPotArc has priority.
Switch between two jobs by briefly pressing the torch but-
ton in TipTronic mode.
(if function 4-stroke 2 and 4-stroke TT = on, the saved jobs
are switched in the active set)
Switch over the remote controller master reference voltage
to 0...10 V
Electrode mode is available when connected to the wire
feed case
When "on", the hold display mode is ended after briefly
pressing the torch key.
With Job Switch On and activated Tiptronic function, you
can move forward to the next active job in the job set by
briefly pressing the torch switch button (< 0.3 sec) (not in
spot mode).
Adjustment range for the minimum gas flow rate 0.0...20
(0.0 = Gas flow monitor is deactivated)
- 59 -