3.17 Technical specifications - Eolo Star 23 kW.
ES
Rated heating power
Min. heating power
Rated heat output (useful)
PT
Min. heat output (useful)
Useful thermal efficiency at rated output
Useful thermal efficiency at 30% rated output
Heat loss at shell with burner On/Off
GR
Heat loss at flue with burner On/Off
PL
Gas nozzle diameter
Supply pressure
Max. working pressure heating circuit
TR
Max. working temperature heating circuit
Adjustable heating temperature
Total volume heating expansion tank
Heating expansion tank precharge
CZ
Generator water capacity
Head available with flowrate 1000/h
Hot water production available heat output
Domestic hot water adjustable temperature
CS
Domestic circuit flow limiter
Domestic circuit min. pressure (dynamic)
Domestic circuit max. working pressure
SI
Min. drawing domestic hot water
Drawing capacity in continuous duty (∆T 30°C)
Specific capacity (∆T 30°C)
Weight of boiler full
HU
Weight of boiler empty
Electrical connection
Rated absorption
RU
Installed electrical power
Power absorbed by circulating pump
Power absorbed by fan
Appliance electrical system protection
RO
Mass flow of fumes at rated power
IE
Mass flow of fumes at min. power
CO
at Q. Rated/Min.
2
CO with 0% O
at Q. Rated/Min.
2
NOX with 0% O2 at Q. Rated/Min.
Temperature of fumes at rated power
Temperature of fumes at min. power
NO
class
X
NO
weighted
X
CO weighted
Type of appliance
Category
- Fume temperature values refer to an air inlet temperature of 15°C.
- The data relevant to domestic hot water performance refers to a dynamic
inlet pressure of 2 bar and an inlet temperature of 15°C; the values are
measured directly at the boiler outlet considering that to obtain the data
declared, mixing with cold water is necessary.
284
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
G20
mm
1,25
mbar (mm H
O)
20 (204)
2
bar
°C
°C
l
bar
l
kPa (m H
O)
2
kW (kcal/h)
°C
l/min
bar
bar
l/min
l/min
l/min
kg
kg
V/Hz
A
W
W
W
-
G20
kg/h
52
kg/h
51
%
6,9 / 2,1
ppm
53 / 53
ppm
62 / 17
°C
107
°C
83
-
mg/kWh
mg/kWh
C12 /C32 / C42 / C52 / C82 / B22 / B32
II2H3+
- The max. sound level emitted during boiler operation is < 55dBA. The
sound level value is referred to semianechoic chamber tests with boiler
operating at max. heat output, with extension of fume exhaust system
according to product standards.
25,1 (21586)
7,9 (6834)
23,8 (20485)
7,0 (6000)
94,9
91,1
0,4 / 0,54
4,7 / 0,02
G30
G31
0,76
0,76
29 (296)
37 (377)
3
90
35 - 80
4,0
1,0
4,0
25,5 (2,6)
23,8 (20485)
35 - 55
8
0,3
10
1,5
11,1
10,7
38
34
230/50
0,79
135
73
43
IPX4D
G30
G31
52
54
42
44
8,0 / 3,0
7,7 / 2,8
79 / 66
28 / 15
80 / 20
75 / 20
105
109
86
83
3
106
89