Section 5
Page 22
Position number
1
2
3
5.2
Operation
5.2.1
Heated Banquet Trolleys
WARNING
WARNING
CAUTION
CAUTION
Banquet trolley heated | neutral
BKW1/14 L-GN | BKW1/20 L-GN | BKW1/36 B-GN | BKW1/14 L-GN+5PK | BKW1/28 B-GN+10PK | BKW1/23 L-GN
Control
Safety temperature limiter button
On/off rotary switch with thermostat
Control lamp
Hazard caused by hot surfaces
If the thermostat is set to position 3 and higher, the permitted maximum tem-
perature of 149°F (65°C) for touchable appliance surfaces can be exceeded.
This can cause burns.
The appliance set to the level 4 may only be operated by an instructed staff.
Wear suitable protective clothing.
Danger of escaping steam
Hot steam can escape when opening the door. Risk of burning.
Please maintain a safe distance and wait until the steam has volatilised.
Damage to the connecting lead
If the holder on the side of models BKW1/36 or BKW1/28 is used for hanging
the connecting lead, the latter may get damaged when the appliance is
moved.
Due to the width of the design of these models, the connecting lead would no
longer be protected by the bumper strips in this case.
Always reel up the connecting lead on the holders provided at the thermal
module before moving the appliance.
Appliance damage
The mains plug of the appliance may not be inserted or pulled out when load-
ed. The appliance must be switched off (marking on the on/off rotary switch
with thermostat faces upward). Only in case of emergency may the plug be
pulled out when loaded.
Always ensure that the appliance is switched off before you insert the mains
plug or pull it out.
Function
Springs out if the safety temperature limiter has
been triggered.
Controls heating and maintains the selected
temperature.
The switch positions of the on/off rotary switch
with thermostat correspond to the following tem-
peratures:
0
off
1
approx. 77°F (25°C)
2
approx. 122°F (50°C)
3
approx.167°F (75°C)
4
approx. 203°F (95°C).
Light is on if the heating runs and functions
properly. If the temperature has been achieved,
the control lamp goes off.
Operation
Operation
91101983_A4