Operation Of The Unit; Operator - KEB COMBIVERT F5 Serie Manual De Instrucciones

Ocultar thumbs Ver también para COMBIVERT F5 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 143
2.
Operation of
the Unit
2.1 Digital Operator
5
4
3
2
1
9
8
7
6
RS232-cable 3m
PC / Operator
Part. No. 00.58.025-001D
As an accessory to the local or external (option: cable 00.F5.0C0-1xxx)
programming an operator is necessary. To prevent malfunctions, the inverter
must be brought into nOP status before connecting / disconnecting the operator
(open control release terminal). When starting the inverter whitout an operator,
it is started with the last stored values or factory setting.
Digital Operator Standard: Part No. 00.F5.060-1000
Interface Operator with serial Interface: Part No. 00.F5.060-2000
Interface control
Transmit "LED on"
(only 00.F5.060-2000)
Only use the operator interface for the serial data transfer to RS232/485. The
direct connection, PC to the inverter is only valid with a special cable (HSP5
Part No. 00.F5.0C0-0001), otherwise, it would lead to the destruction of the PC-
interface.
PIN
RS485
Signal
1
2
TxD
3
RxD
4
A'
RxD-A
5
B'
RxD-B
6
VP
7
C/C'
DGND
8
A
TxD-A
9
B
TxD-B
9-pole SUB-D coupling
Housing (PE)

Operation of the Unit

START
ENTER
FUNC.
F/R
SPEED
STOP
X6B
COMBIVERT
X6C
Meaning
reserved
Transmitter signal/RS232
Receiver signal/RS232
Receiver signal A/RS485
Receiver signal B/RS485
Voltage supply-Plus +5V (I
Data reference potential
Transmitter signal A/RS485
Transmitter signal B/RS485
9-pole SUB-D connector
2
3
5
PC
F5-Operator
5-digit LED Display
Operating-/Error display
Normal "LED on"
Error "LED blinks"
Double function keyboard
RS232/RS485
(only 00.F5.060-2000)
= 10 mA)
max
2
3
7
GB - 9
GB
GB

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Combivert f5 compactCombivert f5 generalCombivert f5 basic

Tabla de contenido