ECL-76, ECL-102
7.8
DC-Kit3 with Dometic FreshJet1100/1700/2200,
FreshLight1600/2200
Roof air conditioner:
– Dometic FreshJet 1100/1700/2200
– Dometic FreshLight1600/2200
Circuit diagram:
– Dometic FreshJet 1100/1700/2200: fig. a, page 13
– Dometic FreshLight1600/2200: fig. b, page 14
Charging current distributor: ECL-102
Inverter: SinePower SP1500 (item no. MSK1500-012)
➤ Install inverter remote control C (membrane button) in an easily-accessible place and
connect its cable to the inverter.
➤ Remove the FreshJet/FreshLight's outlet panel, if necessary remove the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable (item no. 9102700006) of the FreshJet 1100/1700/2200 or
FreshLight1600/2200 to the plug connector on the circuit board (fig. g, page 18 for
FreshJet and fig. h, page 18 for FreshLight).
NOTE
I
Guide the on/off cable carefully past the fan.
➤ Connect both the wires on the universal connection cable (item no. 4441300124) to the
two wires on the on/off cable of the FreshJet 1100/1700/2200 or FreshLight1600/2200.
7.9
DC-Kit4 with Dometic B2600
Roof air conditioner: B2600
Circuit diagram: fig. c, page 15
Charging current distributor: ECL-102
Inverter: SinePower MSP2012 (item no. MSP2000-012)
➤ Install inverter remote control MCR-9 (membrane button) in an easily-accessible place
(jumper closed, refer to remote control installation manual) and connect its cable to the
inverter.
➤ Remove the B2600's outlet panel, if necessary remove the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable of the B2600 (item no. 4441300129) to the plug connector on the
circuit board (fig. i, page 19).
EN
Connection
73