Gate movement programming procedure
• Before starting programming:
- make sure the opening and closing travel limit buffers have been installed;
- move the gate to about thirty centimetres from the mechanical closing buffer. This will allow you to
check that the gate's first movement is in the closing direction;
- lock the gate to the geared motor (see paragraph 'manual release' in the instruction manual supplied
with the automation;
- Make sure the safety devices
and that there are no active
background);
- If you have safety devices working with 8.2KΩ contacts select the correct setting from the menu
;
SAFETY DEVICES
- make sure that the ECU is receiving MAINS POWER with the
Attention: it is not possible to enter programming when working off battery power
- set the main operating parameters (e.g. right/left installation, electric lock etc.) in the
menu and choose the correct motor type in the
Automatic programming
•
• The digital display will show the main screen with the indication 'PROGRAM' flashing.
• Press 'PROG/OK' for 4 seconds, 'PAUSE' will appear on the display.
TB
-
FS
-
FI
-
CP
are at rest (white characters on a black background)
TA - TC - FD - TAL commands (at rest =
MOVEMENT
black characters on a white
symbol on the display;
;
OPTIONS
menu;
PROG/OK
76
Stop buffers
SL
BL
HL
PROGRAM
TB
FI
FS
CP
00.000.007
07-06-16
PAUSE
TB
FI
FS
CP
AUTO PROG
00.000.007
4s
07-06-16
TA
FD
TC
TAL
15.35
TA
FD
TC
TAL
15.35