Cardin Elettronica SL Serie Manual Del Usuario página 58

Centrales multifuncionales para automatizaciones autoprogramables
Ocultar thumbs Ver también para SL Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 178
4f) Gate delay during opening
• Press PROG/OK to scroll between the available choices:
- 0 steps; 1 step; 2 steps (default setting); 3 steps; 4 steps; 5 steps; 6 steps; 7 steps; 8 steps; 9 steps
• Press the arrow button
choice and move to the next parameter.
Setting the gate delay between the two gate leaves (encoder count) in opening and consequently in closing. it
only tales effect if parameter 5n 'Opening direction gate delay' in the options menu is set to 'ON'.
4g) Close brake room
• Press PROG/OK to scroll between the available choices:
- Setting 0 = disabled (default setting); Setting 1 = minimum distance
Setting 2 = medium distance; Setting 3 = maximum distance
• Press the arrow button
choice and move to the next parameter.
Setting the braking room towards the end of the closing stage.
4h) Close brake speed
• Press PROG/OK to scroll between the available choices:
- Setting 1 = low speed; Setting 2 = medium speed; Setting 3 = high speed
• Press the arrow button
choice and move to the next parameter.
Setting the braking speed during closing. The default parameter is '1' but it only tales effect if parameter 4g
'close braking room' is set to 1, 2 or 3.
to confirm the choice eg. 3 steps. The programmer will save the
to confirm the choice eg. Setting 2. The programmer will save the
to confirm the choice eg. Setting 3. The programmer will save the
58
4f) Gate delay
LIMITED
OPENING
3 METERS
DIST. FROM CLOSE
4 STEPS
GATE DELAY
3 STEPS
4g) Close brake room
DIST. FROM CLOSE
4 STEPS
GATE DELAY
3 STEPS
CLOSE BRAKE ROOM
SETTING 2
4h) Close brake speed
GATE DELAY
3 STEPS
CLOSE BRAKE ROOM
SETTING 2
CLOSE BRAKE SPEED
SETTING 3