• Now we want the gate to open at 08:20 on Saturday, remain open for 20 minutes and then close
at 08:40. The gate then opens at 12:30, remains open for 15 minutes and closes at 12:45.
• Press
to scroll to event 4 and press 'PROG/OK' and then the arrow key again
- with
highlighted, press
MO-FR
the opening command
TA
below:
EVENT
INTERVAL
4
5
6
7
Attention: if automatic reclosing is disabled the same sequence will require 14 events. Each pair of TA
opening commands (status 1 and 0) will have to be followed by two closing commands TC (status 1 and 0).
Automatic reclosing will start after the pause time set in parameter 4i has elapsed. Therefore, with a pause
time of 60 seconds, events 1, 3, 5 and 7 will effectively take place one minute after the programmed time
at 08:11, 08:16, 08:41 and 12:46.
until
SATURDAY
set the status to
then set the other three events by following table
1
TIME
SA
08:20
SA
08:40
SA
12:30
12:45
SA
appears, set the time to 08:20, select
COMMAND
STATUS
TA
1 (ON)
TA
0 (OFF)
TA
1 (ON)
TA
0 (OFF)
74
MO-FR 08:15 TA 0
:
SATURDAY 08:20 TA 1
SATURDAY 08:40 TA 0
SATURDAY 08:40 TA 0
SATURDAY 12:20 TA 1
SATURDAY 12:40 TA 0
EVENT 3
EVENT 4
EVENT 5
EVENT 5
EVENT 6
EVENT 7